paravalvular leak
4
leak mitral
4
mitral valve
4
valve replacement
4
replacement source
4
source regurgitant
4
regurgitant jet?
4
paravalvular
1
mitral
1
valve
1

Similar Publications

Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.

Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.

View Article and Find Full Text PDF

Background: Mitral annular calcification (MAC) is characterized by severe calcification of mitral annulus and might be associated with both mitral regurgitation and stenosis. It is technically challenging for both surgical and percutaneous approach and is burdened by high mortality.

Case Summary: The present case report describes a complex case of mitral steno-insufficiency (baseline transvalvular gradient = 5 mmHg, effective regurgitant orifice area 0.

View Article and Find Full Text PDF

The Ross procedure provides young patients with unrepairable aortic valve disease with a living pulmonary autograft that confers significant survival benefit and improved quality of life. However, the procedure is complicated, and surgeons can be reluctant to offer it as a solution, especially in complex re-operative scenarios. We present a young patient with symptomatic, severe aortic insufficiency who had undergone two failed aortic valve procedures for congenital bicuspid aortic valve disease within the prior year.

View Article and Find Full Text PDF

Background: The self-expanding, supra-annular Evolut valve is an established platform for Transcatheter Aortic Valve Implantation (TAVI). Evolut PRO introduced an outer sealing wrap to mitigate paravalvular leakage. We evaluated the 3-year clinical outcomes and valve performance of the Evolut PRO in standard clinical practice for severe aortic stenosis (AS) patients at intermediate or higher risk for surgery.