Optical characteristics of experimental dental composite resin materials.

J Dent

The Ohio State University, College of Dentistry, Division of Restorative and Prosthetic Dentistry, Columbus, OH 43210 USA. Electronic address:

Published: March 2022

Objectives: To derive the K-M optical coefficients of experimental composites and compare the inherent CIE L*, a* and b* color parameters, translucency parameters and both perceptibility and acceptability thresholds.

Methods: Experimental composites were prepared with 4 base-monomers: Bis-GMA, UDMA, Bis-EMA and Fit852 with TEGDMA used as a co-monomer and 3 filler:resin fractions (50:50wt%, 60:40wt% and 70:30wt%). The optical absorption (K) and scattering (S) coefficients over the visible spectra were derived. Corrected reflectivity spectra were calculated using the corrected Kubelka-Munk reflectance model and were used to calculate CIE color parameters (X, Y, Z) values. Translucency parameter (TP) was calculated using the CIEDE2000 color difference. A three-way repeated measures ANOVA was used to analyze the CIE L*a* and b* color parameters at infinite thickness. A two-way ANOVA was used to analyze the translucency parameter at 2 mm thickness. Pairwise comparisons were assessed using Bonferroni-corrected Student's t-tests. For all statistical testing α = 0.05 was used. Color parameters (ΔE) were calculated for every experimental composite using the CIEDE2000 color differences. Perceptibility threshold (PT), acceptability threshold (AT) and translucency differences (ΔTP) were used to compare experimental composites in both filler fraction within every resin and every resin within each filler fraction.

Results: The statistical analysis revealed a 3-way interaction (P < 0.0001) between base monomer, filler and direction factors. For the translucency parameter, when comparing filler fraction within base monomers, there were statistically significant differences between the filler fraction within all base monomers. The analysis of color differences (ΔE) of base monomers within filler fraction revealed that the comparison between experimental composites where beyond the acceptability threshold. The comparison of the differences in translucency parameter (ΔTP) of base monomers within filler fraction were beyond the perceptibility threshold, except between base monomers UT and FT.

Significance: Different base monomer and filler fraction combination influences the optical characteristics of experimental composites such as: light transmission, translucency, and color appearance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2022.103949DOI Listing

Publication Analysis

Top Keywords

filler fraction
24
experimental composites
20
base monomers
20
color parameters
16
translucency parameter
16
optical characteristics
8
characteristics experimental
8
color
8
cie color
8
ciede2000 color
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!