A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fast antibiotic susceptibility testing of urine microflora using a microbiological analyzer based on coherent fluctuation nephelometry. | LitMetric

Background: Traditional culture-based microbiological methods remain the most used for defining the etiology of urinary tract infections and antibiotic susceptibility testing (AST) of isolated uropathogens. They are time-consuming and lead to delays of several days when obtaining the final results of microbiological tests.

Objectives: In this study, we validate the possibility of using a microbiological CFN analyzer combined with MALDI-TOF mass spectrometry (MS) for fast conclusive urine testing (1 day) without obtaining pure cultures.

Materials And Methods: The study included three stages: detection of urine microflora growth using the CFN analyzer to separate positive and negative samples within 2-4 h; fast MS identification of positive samples without isolating uropathogens; fast AST using CFN analyzer within 3-6 h. In parallel, all urine samples were tested by traditional culture-based microbiological methods.

Result: In total, 194 urine samples were tested, and 22 urine cultures were identified by MS, among them, 20 monocultures with bacterial counts ≥ 10 and 2 mixed cultures. The AST of these 22 urine cultures and additional 88 pure clinical cultures was performed using eight antibiotics. Overall, 276 tests were performed. The results of AST obtained using the CFN analyzer and traditional methods were in good agreement (98.2%). Although two mixed cultures were falsely identified as monocultures, their susceptibility determined by the CFN analyzer was correct.

Conclusions: The CFN analyzer is promising and effective for fast AST. Combined with MS identification, it allows to perform full urine analysis in 1 day without the lengthy isolation of pure cultures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8882479PMC
http://dx.doi.org/10.1007/s42770-021-00671-4DOI Listing

Publication Analysis

Top Keywords

cfn analyzer
24
antibiotic susceptibility
8
susceptibility testing
8
urine
8
urine microflora
8
traditional culture-based
8
culture-based microbiological
8
fast ast
8
ast cfn
8
urine samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!