Determination of Nanoplastics Using a Novel Contactless Conductivity Detector with Controllable Geometric Parameters.

Anal Chem

Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology, Beijing 100124, China.

Published: January 2022

Plastic waste in the environment is continuously degraded to form nanoplastic particles, and its harm has attracted widespread attention. At present, the identification and quantification of nanoplastics are performed by visual observation and using some spectroscopy methods, which are time-consuming and lack accuracy. Therefore, this study proposes a contactless conductivity detector (CD) based on a glass microfluidic chip with controllable geometric parameters to quantify nanoplastics. We found that when the insulating layer thickness was 15 μm, the electrode spacing was 1 mm, and the shielding method was on-chip shielding, the detector displayed the best performance. The detector possesses a simple structure with high sensitivity and outstanding reproducibility, that is, the limit of detection of KCl solutions can reach the micromolar level, and the intraday RSD is 0.2% ( = 5). This work uses a microfluidic chip CD to study nanoplastics for the first time, and the limit of detection is 0.25 μg/mL and the quantitative limit is 0.8 μg/mL. In addition, plant experiments have verified that terrestrial plants can absorb nanoplastics in water, expanding the application of contactless conductivity detectors and providing a new method for the quantitative analysis of nanoplastics.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.1c02752DOI Listing

Publication Analysis

Top Keywords

contactless conductivity
12
conductivity detector
8
controllable geometric
8
geometric parameters
8
microfluidic chip
8
limit detection
8
nanoplastics
5
determination nanoplastics
4
nanoplastics novel
4
novel contactless
4

Similar Publications

This paper introduces a novel contactless single-chip detector that utilizes impedance-to-digital conversion technology to measure impedance in the microfluidic channel or capillary format analytical device. The detector is designed to operate similarly to capacitively coupled contactless conductivity detectors for capillary electrophoresis or chromatography but with the added capability of performing frequency sweeps up to 200 kHz. At each recorded data point, impedance and phase-shift data can be extracted, which can be used to generate impedance versus frequency plots, or phase-shift versus frequency plots.

View Article and Find Full Text PDF

Magneto-responsiveness in living organisms, exemplified by migratory birds navigating vast distances, offers inspiration for soft robots and human-computer interfaces. However, achieving both high magneto-responsiveness and resilient mechanical properties in synthetic materials has been challenging. Here, we develop magneto-iono-elastomers (MINEs), combining exceptional magnetization [2.

View Article and Find Full Text PDF

HealthPass: a contactless check-in and adaptive access control system for lowering cluster infection risk in public health crisis.

Front Public Health

December 2024

Fujian Key Laboratory of Sensing and Computing for Smart Cities, School of Informatics, Xiamen University, Xiamen, China.

Introduction: Ensuring effective measures against the spread of the virus is paramount for educational institutions and workplaces as they resume operations amidst the ongoing public health crisis. A touchless and privacy-conscious check-in procedure for visitor assessment is critical to safeguarding venues against potential virus transmission.

Methods: In our study, we developed an interaction-free entry system featuring anonymous visitors who voluntarily provide data.

View Article and Find Full Text PDF

A client-server based recognition system: Non-contact single/multiple emotional and behavioral state assessment methods.

Comput Methods Programs Biomed

December 2024

School of Communication and Information Engineering, Shanghai University, 200444, Shanghai, China. Electronic address:

Background And Objectives: In the current global health landscape, there is an increasing demand for rapid and accurate assessment of mental states. Traditional assessment methods typically rely on face-to-face interactions, which are not only time-consuming but also highly subjective. Addressing this issue, this study aims to develop a client-server-based, non-contact multimodal emotion and behavior recognition system to enhance the efficiency and accuracy of mental state assessments.

View Article and Find Full Text PDF

Vital signs such as heart rate (HR) and respiration rate (RR) are essential physiological parameters that are routinely used to monitor human health and bodily functions. They can be continuously monitored through contact or contactless measurements performed in the home or a hospital. In this study, a contactless Doppler radar W-band sensing system was used for short-range, contactless vital sign estimation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!