Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To predict cycloplegic refractive error using measurements obtained under noncycloplegic conditions.
Method: Refractive error was measured in 5- to 18-year-old Chinese students using a NIDEK autorefractor before and after administration of 0.5% tropicamide. Spherical equivalent (SER) in diopters (D) was calculated as sphere plus half cylinder. A multivariable prediction model for cycloplegic SER was developed using data from students in Jinyun (n = 1938) and was validated using data from students in Hangzhou (n = 1498). The performance of the prediction model was evaluated using R2, mean difference between predicted and measured cycloplegic SER, and sensitivity and specificity for predicting myopia (cycloplegic SER ≤ -0.5 D).
Results: Among 3436 students (mean age, 9.7 years; 51% female), the mean (SD) noncycloplegic and cycloplegic SER values were -1.12 (1.97) D and -0.20 (2.19) D, respectively. The prediction model that included demographics, noncycloplegic SER, axial length/corneal curvature radius ratio, uncorrected visual acuity (UCVA), and intraocular pressure predicted cycloplegic SER with R2 of 0.93 in the development dataset and 0.92 in the validation dataset. The mean (SD) differences between predicted and measured cycloplegic SER were 0.0 (0.55) D in the development dataset and 0.06 (0.64) D in the validation dataset. In both the development and validation datasets, the combination of predicted SER and UCVA yielded high sensitivity (91.4% and 91.9%, respectively) and specificity (95.0% and 90.1%, respectively) for detecting myopia.
Conclusions: Cycloplegic refractive error can be predicted using measurements obtained under noncycloplegic conditions. The prediction model could potentially be used to correct the myopia prevalence in epidemiological studies in which administering cycloplegic agent on all participants is not feasible.
Translational Relevance: The prediction model may provide a tool for correcting the overestimation of myopia from noncycloplegic refractive error in future epidemiological studies in which administering cycloplegic agent on all participants is not feasible.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8762687 | PMC |
http://dx.doi.org/10.1167/tvst.11.1.15 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!