Objective: To evaluate the impact of pathogen-reduced (PR) platelet transfusions on blood products requirement for clinical practice.

Background: PR platelets are increasing in use as standard blood products. However, few randomised trials have evaluated their impact on bleeding control or prevention. Furthermore, PR platelets recirculate less than untreated platelets.

Methods: A subgroup study of the randomised clinical trial EFFIPAP compared three arms of platelet preparations (PR: P-PRP/PAS, additive solution: P-PAS and plasma P-P arms respectively). The subgroup of acute leukaemia patients, in their chemotherapy induction phase, included 392 patients (133 P-PRP/PAS arm, 132 P-PAS arm and 130 P-P arm). Blood requirements were analysed across over periods of 7 days.

Results: The number of platelet transfusions per week was significantly higher in the P-PRP/PAS group 2.3 [1.6-3.3] compared to the control groups 1.9 [1.3-2.8] and 2.0 [1.3-3.0] for P-P and P-PAS groups respectively (p < 0.0001). However, the total number of platelets transfused per week was not different. The number of red blood cell concentrates (RBC) transfusion per week did not differ either.

Conclusion: In a homogeneous group of patients, platelet pathogen reduction resulted in an increased number of platelet units transfused per week while having no impact on the total number of platelets transfused or the number of RBC transfusion; resulting to an average requirement of 2 RBC and 2-3 platelets transfusions per week of marrow aplasia.

Download full-text PDF

Source
http://dx.doi.org/10.1111/tme.12848DOI Listing

Publication Analysis

Top Keywords

impact pathogen-reduced
8
acute leukaemia
8
platelet transfusions
8
blood products
8
pathogen-reduced platelets
4
platelets acute
4
leukaemia treatment
4
treatment total
4
blood
4
total blood
4

Similar Publications

Background: Splitting apheresis platelet (PLT) units increase available inventory during shortages. The impact of prolonged storage in gas-impermeable aliquot bags on PLT quality in vitro and transfusion outcomes in patients remains uncertain.

Study Design And Methods: We assessed in vitro PLT quality and thromboelastography (TEG) in PLTs stored for 8 or 24 h in aliquot bags compared with baseline (T0).

View Article and Find Full Text PDF

Background And Objectives: Honduras became the first lower middle-income country (LMIC) to adopt amotosalen/UVA pathogen-reduced (PR) platelet concentrates (PCs) as a national platelet safety measure in 2018. The Honduran Red Cross (HRC) produces ~70% of the national platelet supply using the platelet-rich plasma (PRP) method. Between 2015 and 2018, PCs were screened with bacterial culture and issued as individual, non-pooled PRP units with weight-based dosing and 5-day shelf-life.

View Article and Find Full Text PDF

Background: Kaiser-Permanente Los Angeles Medical Center (LAMC) is a 560 licensed bed facility that provides regional cardiovascular services, including 1200 open heart surgeries annually. In 2021, LAMC explored alternative therapies to offset the impact of pandemic-driven cryo AHF shortages, and implemented Pathogen Reduced Cryoprecipitated Fibrinogen Complex (also known as INTERCEPT Fibrinogen Complex or IFC). IFC is approved to treat and control bleeding associated with fibrinogen deficiency.

View Article and Find Full Text PDF

Isohemagglutinin titration in pooled and apheresis platelets.

Transfusion

July 2024

Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada.

Background: Platelet inventory constraints necessitate ABO-incompatible platelet transfusion. Many minimize the hemolytic impact by confirming low titre (LT) donor isohemagglutinins. This process is costly.

View Article and Find Full Text PDF

Background And Objectives: Pathogen reduction (PR) technology may reduce the risk of transfusion-transmitted infections (TTIs), notably transfusion-transmitted bacterial infection (TTBI) associated with platelet concentrates (PCs). PR (amotosalen/UVA treatment) was implemented for all PCs transfused in France in November 2017. No bacterial detection was in place beforehand.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!