Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Robotic prostatectomy requires pneumoperitoneum and a steep Trendelenburg position; however, this condition may compromise cerebral blood flow. Here, we evaluated the effect of pneumoperitoneum and the steep Trendelenburg position on internal carotid artery (ICA) blood flow measured by Doppler ultrasound during robotic prostatectomy.
Methods: Patients who underwent robotic prostatectomy were prospectively recruited. The ICA blood flow was measured at the following five time-points: with the patient awake and in the supine position (Ta), 10 min after anaesthetic induction in the supine position (T1), 10 (T2) and 30 (T3) min after pneumoperitoneum in the steep Trendelenburg position, and at the end of surgery in the supine position after desufflation of the pneumoperitoneum (T4). Hemodynamic and cerebrovascular variables were measured at each time-point.
Results: A total of 28 patients were evaluated. The ICA blood flows were significantly lower at T2 and T3 than at T1 (162.3 ± 44.7 [T2] vs. 188.0 ± 49.6 ml/min [T1]; p = .002, 163.1 ± 39.9 [T3] vs. 188.0 ± 49.6 ml/min [T1]; p = .009). The ICA blood flow also differed significantly between Ta and T1 (236.8 ± 58.3 vs. 188.0 ± 49.6 ml/min; p < .001). Heart rates, cardiac indexes, peak systolic velocity, and end-diastolic velocity were significantly lower at T2 and T3 than at T1. However, ICA diameter, mean blood pressure, and end-tidal carbon dioxide partial pressure did not differ significantly at all time-points.
Conclusion: Pneumoperitoneum and the steep Trendelenburg position caused decreased ICA blood flow, suggesting that they should be carefully performed during robotic prostatectomy, especially in patients at risk of postoperative cerebrovascular accident.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cpf.12742 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!