The change in the pinning force during the transition from dry to oil-impregnated thin polymer films is studied for droplets of water and hexadecane. A careful variation of the oil amount in the films is performed by means of supercritical impregnation. The film thickness dependence on the oil content is measured using ellipsometry and compared to gel swelling theory estimates. Depending on the oil content, two cases of pinning force behavior have been identified. For each case, the factors that determine the pinning force are discussed. The pinning force in the transition from dry to equilibrium swollen gel films is well approximated by the Joanny and de Gennes hysteresis model of dilute defects.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.1c02767DOI Listing

Publication Analysis

Top Keywords

pinning force
20
force transition
12
transition dry
12
thin polymer
8
polymer films
8
oil content
8
pinning
5
force
5
study droplet
4
droplet pinning
4

Similar Publications

Background: Bennett's fracture, a fracture-dislocation of the base of the first metacarpal, poses significant challenges due to the unique biomechanics of the thumb's carpometacarpal (CMC) joint. Effective management is critical to restoring thumb function and preventing long-term complications such as arthritis and instability.

Objective: This article provides a comprehensive overview of Bennett's fracture, including its mechanism of injury, diagnostic considerations, and management strategies, with a focus on conservative and surgical options.

View Article and Find Full Text PDF

Despite the importance of the effect of subnanoscale roughness on contact line behavior, it is difficult to directly observe the local behavior of contact lines at the micro- and nanoscale, leaving significant gaps in our current understanding. In this research, we investigate contact line motions and their relationship with nanoscale surface topography using coherence scanning interferometry. Our experiments were conducted on the substrates with different wettability without changing nanoscale surface topography.

View Article and Find Full Text PDF

Objective: Calcaneal fracture fixation remains a challenging procedure in orthopedics, with computational tools increasingly aiding in the optimization of preoperative planning. To compare the biomechanical stability of intramedullary fixation and locking plate fixation for Sanders II and III calcaneal fractures by three-dimensional (3D) finite element analysis and to provide a theoretical basis for clinical application.

Methods: The Computed Tomography (CT) images were segmented using Mimics software (Materialise NV, Belgium) to identify the region of interest based on threshold segmentation.

View Article and Find Full Text PDF

Forced one-dimensional swarmalator model.

Phys Rev E

November 2024

Senseable City Lab, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.

We study a simple model of swarmalators subject to periodic forcing and confined to moving around a one-dimensional ring. This is a toy model for physical systems with a mix of sync, swarming, and forcing, such as colloidal micromotors. We find rich behavior: pinned states where the swarmalators are locked to the driving, sync states where their phases are either identical or have fixed differences, and unsteady states, such as swarmalator chimera where the population splits into two sync dots enclosed by a "train" of swarmalators that run around a peanut-shaped loop.

View Article and Find Full Text PDF

Background: The anatomy of the proximal tibia presents treatment challenges, and there is currently no widely accepted surgical fixation method for fractures in this region. The aim of this study is to evaluate the efficacy, benefits, and differences between intramedullary nailing (IMN) with a 4-hole Limited Contact Dynamic Compression Plate (LC-DCP) combination and IMN with an 8-hole LC-DCP combination in unstable fractures of the proximal metaphyseal region of the tibia.

Methods: An oblique fracture was created in the metaphyseal region, forming a 30-degree angle in the sagittal plane in three tibial models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!