The present study aimed to evaluate if commonly used endodontic irrigants such as 3% sodium hypochlorite (NaOCl, Prime Dental, Thane, India), 2% chlorhexidine (CHX, Sigma-Aldrich Co., St. Louis, MO, USA), and 17% ethylenediaminetetraacetic acid (EDTA, Meta-Biomed Co. Ltd., Cheongju-si, South Korea) influenced the setting time and metal composition of different base endodontic sealers on exposure. AH Plus (Dentsply De Trey GmbH, Konstanz, Germany), Sealapex (SybronEndo, Orange, CA, USA), mineral trioxide aggregate (MTA) Fillapex (Angelus Soluções Odontológicas, Londrina, Brazil), and Tubli-Seal (Kerr Dental, Orange, CA, USA) were selected as the different base representatives of endodontic sealers. These sealers were exposed to 3% NaOCl, 2% CHX, and 17% EDTA, and the individual setting time of the sealers was analyzed. The samples were analyzed for heavy metal elements such as chromium (Cr), nickel (Ni), cobalt (Co), cadmium (Cd), arsenic (As), mercury (Hg), lead (Pb), and beryllium (Be) by using inductively coupled plasma mass spectrometry (ICP-MS) analysis. For statistical analysis, one-way ANOVA and post hoc Tukey's tests were used. All selected sealers showed variation in setting time post-exposure to different irrigants. MTA Fillapex had the shortest mean setting time (215.7 min, post-exposure at 187.3 min) ( < 0.05). Mean setting time was also affected for AH Plus (479.6 min, post-exposure at 423.9 min) ( < 0.05) and Tubli-Seal (514.7 min, post-exposure at 465.2 min) ( < 0.05). Sealapex showed the maximum reduction of setting time (864.8 min, post-exposure at 673.4 min) ( < 0.05). All tested sealers showed heavy metals (Cr, Ni, Co, Cd, As, Hg, and Pb) in their composition, and the quantities were influenced by interaction with different irrigants. The heavy metal Be was not seen in any of the samples. Sealapex showed the longest setting time in comparison to other test sealers. Heavy metals were most present in Sealapex, followed by AH Plus, Tubli-Seal, and MTA Fillapex. MTA Fillapex was seen to have the shortest setting time, and heavy metal composition was least affected on interaction with different commonly used endodontic irrigants. Further, this study provides significant insight into the influence of different endodontic irrigants on interaction with different base endodontic sealers, which has not been reported previously, and future studies should emphasize endodontic irrigant-sealer interactions and their possible effects in the long run.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747268PMC
http://dx.doi.org/10.3390/polym14010027DOI Listing

Publication Analysis

Top Keywords

setting time
36
endodontic irrigants
16
endodontic sealers
16
mta fillapex
16
min post-exposure
16
min 005
16
commonly endodontic
12
metal composition
12
base endodontic
12
heavy metal
12

Similar Publications

Background Orthodontic diagnostic workflows often rely on manual classification and archiving of large volumes of patient images, a process that is both time-consuming and prone to errors such as mislabeling and incomplete documentation. These challenges can compromise treatment accuracy and overall patient care. To address these issues, we propose an artificial intelligence (AI)-driven deep learning framework based on convolutional neural networks (CNNs) to automate the classification and archiving of orthodontic diagnostic images.

View Article and Find Full Text PDF

Background: The COVID-19 pandemic and its accompanying safeguards intensified many of the ongoing daily challenges faced by caregivers of young people with chronic kidney disease (CKD) both pre-transplant and post-transplant, and also created a variety of new and pressing concerns. Little is known about how these families managed this unexpected adversity in their lives.

Objective: To evaluate change in psychosocial risk for families of young people with CKD during the COVID-19 pandemic health emergency from the perspective of caregivers.

View Article and Find Full Text PDF

This study aimed to evaluate the impact of different manipulation methods and storage environments on the microstructural, chemical, and mechanical properties of calcium-enriched mixture (CEM) cement. Four sample groups were examined, including nondried (ND-I) and dried (D-I) groups placed directly in an incubator, dried samples stored in phosphate-buffered saline (PBS) (D-P), and dried samples stored in distilled water (D-W). Various analyses, including Vickers microhardness, compressive strength, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) were conducted after incubating the samples for 7 days.

View Article and Find Full Text PDF

Context: Cleaning consists of different activities such as mopping, sweeping, swabbing, dusting, disposing of trash, and buffing. These different physical activities of the cleaners can change the body's normal biomechanics, possibly leading to the development of musculoskeletal disorders over time.

Aims: This study aimed to check the ergonomic risk and its relationship with age, BMI, and work experience among cleaners.

View Article and Find Full Text PDF

Background: Sepsis is a significant health burden on a global scale. Timely identification and treatment of sepsis can greatly improve patient outcomes, including survival rates. However, time-consuming laboratory results are often needed for screening sepsis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!