Exposure to ergonomic risk factors has been reported for laboratory workers over decades. However, these exposures are not well characterized with respect to the type of laboratory or work organization. This study compared biomechanical exposure to upper extremity (UE) postures and hand activity levels (HALs) in general hospital laboratories by job, work, and laboratory type. The study used observational data gathered using a revised version of the Posture, Activity, Tools, and Handling (PATH) method, generating frequencies of categorized exposures. Eighteen workers were observed in 11 job titles (seven laboratories) in a single hospital by two investigators over a 7 month period. A taxonomy was constructed to categorize the extent to which the laboratory operations were automated. Overall, there were markedly high exposures to postural strain for the distal UE, especially wrist/forearm deviation (73% of observations), gross grasp (71%), and pinch grip (49%). For the HAL categories, 61% of the observations were in the moderate range (3.3-<6.7). Shoulders and elbows tended to remain in the neutral postural range. Posture frequencies were similar among the job categories studied and laboratory types. HAL was higher when the hand was in a pinch grip. Manual operations represented a higher proportion of work time than semi-automated or automated operations. Biomechanical exposure can be documented more extensively and diversely when using the revised PATH approach along with the taxonomy, with respect to exposure variables, such as the type of job, work, or organization in the industry including the hospital laboratories.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8744870 | PMC |
http://dx.doi.org/10.3390/ijerph19010499 | DOI Listing |
Life (Basel)
January 2025
Occupational Medicine Unit, Department of Medical and Surgical Sciences, Alma Mater Studiorum University of Bologna, 40138 Bologna, Italy.
Musculoskeletal disorders are the most prevalent occupational health problem and are often related to biomechanical risk factors. Over the last forty years, observational methods for exposure assessment have been proposed. To apply them effectively in the field, an in-depth knowledge of each methodology and a solid understanding of their actual predictive value and limitations are required.
View Article and Find Full Text PDFJ Clin Orthop Trauma
February 2025
Department of Orthopaedics, Sir Harkisandas Narottamdas Reliance Foundation Hospital, Mumbai, Maharashtra, India.
Introduction: Arthroscopic Anterior Cruciate Ligament Reconstruction (ACLR) with internal bracing and augmentation using tape-type sutures (TTS) has gained popularity due to its biomechanical advantages. However, concerns have emerged regarding chronic reactive synovitis, which can lead to graft failure and the need for revision surgery. The purpose of this research is to determine the prevalence of chronic reactive synovitis after TTS-reinforced ACLR.
View Article and Find Full Text PDFSmall Methods
January 2025
State Key Laboratory of Mechanics and Control for Aerospace Structures, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China.
Bionic adhesive materials with 3D complex micro/nanostructures have several advantages of low preload, strong adhesion, switchable adhesion, etc. As the primary high-precision fabrication method for such materials, lithography is inherently limited by its 2D processing capabilities. Achieving complex 3D morphologies typically requires auxiliary processes, such as dipping and double-sided separate UV exposures, which increase both the complexity and limitations of the fabrication process.
View Article and Find Full Text PDFJ Biomech
January 2025
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region.
This study explored how systematic changes in running shoe degradation and foot inversion alter the distribution and peak value of heel pressure and calcaneus stress, as well as the total stress-concentration exposure (TSCE) within the calcaneal bone. A foot-shoe finite element model was employed and three shoe wear conditions (new shoe (CON), moderate worn shoe (MWSC), excessive worn shoe (EWSC)) coupled with three foot inversion angles (0°, 10°, 20°) were further modulated. Simulations were conducted at the impact peak instant during running.
View Article and Find Full Text PDFJSES Int
November 2024
Department of Orthopaedic Surgery, University of Iowa, Iowa City, IA, USA.
Background: Limitations to using the knee as donor cartilage include cartilage thickness mismatch and donor site morbidity. Using the radial head as donor autograft for capitellar lesions may allow for local graft harvest without distant donor site morbidity. The purpose of this study is to demonstrate the feasibility of performing local osteochondral autograft transfer from the nonarticular cartilaginous rim of the radial head to the capitellum.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!