A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of a Single Cell Electric-SRR Metamaterial for Strain Evaluation. | LitMetric

Application of a Single Cell Electric-SRR Metamaterial for Strain Evaluation.

Materials (Basel)

Center for Electromagnetic Fields Engineering and High-Frequency Techniques, Faculty of Electrical Engineering, West Pomeranian University of Technology, ul. Sikorskiego 37, 70-313 Szczecin, Poland.

Published: December 2021

Strain is a crucial assessment parameter in structural health monitoring systems. Microstrip sensors have been one of the new types of sensors used to measure this parameter in recent years. So far, the strain directionality of these sensors and the methods of miniaturization have been studied. This article proposes the use of a single cell metamaterial as a resonator of the microstrip sensor excited through the microstrip line. The proposed solution allowed for significant miniaturization of the microstrip sensor, with just a slight decrease in sensitivity. The proposed sensor can be used to measure local deformation values and in places with a small access area. The presented sensor was validated using numerical and experimental methods. In addition, it was compared with a reference (rectangular geometry) microstrip sensor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746036PMC
http://dx.doi.org/10.3390/ma15010291DOI Listing

Publication Analysis

Top Keywords

microstrip sensor
12
single cell
8
microstrip
5
sensor
5
application single
4
cell electric-srr
4
electric-srr metamaterial
4
metamaterial strain
4
strain evaluation
4
evaluation strain
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!