Background: Interlocking nailing is considered a gold standard surgical treatment of mid-shaft closed diaphyseal tibial fractures. With increasing exposure of orthopaedic surgeons to radiation, we propose a solution to this health hazard through a study wherein we perform the surgery without any radiation or C-arm exposure.

Material And Methods: This prospective study was done at GMC Jammu from January 2017 to February 2020 and included 218 patients, with 18 patients having bilateral tibia fractures in the age group 15 to 58 years (mean of 37.6 years), including 63.7% males (n=139) and 36.3% females (n=79). The 236 extra-articular closed tibial mid-diaphyseal fractures were operated on and intramedullary tibial nailing was performed without a single C-arm exposure. Postoperative x-rays were done and reduction assessed by standard acceptable criteria.

Results: Among 236 cases in which nailing was done, 227 (96%) patients were successfully distally locked, including 128 (56.3%) locked through the jig and 99 (43.6%) by "hit and trial method." All cases met acceptability criteria set for management of tibia by nailing.

Conclusions: 1.This study strengthens the proof that closed extra-articular diaphyseal fractures of the tibia can be managed by nailing without using the C-arm with excellent results. 2.The C-arm is always available for cases where distal locking could not be achieved. 3. The technique has a great role in centres with limited facilities of intra-operative radiography in emergency operation theatres.

Download full-text PDF

Source
http://dx.doi.org/10.5604/01.3001.0015.6372DOI Listing

Publication Analysis

Top Keywords

intramedullary tibial
8
closed extra-articular
8
tibial
5
fractures
5
radiation-free insertion
4
insertion interlocked
4
interlocked intramedullary
4
tibial nail
4
closed
4
nail closed
4

Similar Publications

The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.

View Article and Find Full Text PDF

Background: To compare the efficacy of intramedullary nailing via the lateral parapatellar approach versus the infrapatellar approach in treating fractures at the tibial metaphyseal-diaphyseal junction.

Methods: A retrospective analysis was conducted on the clinical data of 45 patients with proximal or distal tibial fractures treated with intramedullary nailing via lateral parapatellar approach (n = 23) or infrapatellar approach (n = 22) between January 2019 and March 2023. We recorded and compared the operative time, intraoperative blood loss/fluoroscopies, success rate of closed reduction, anteroposterior and lateral entry point accuracy, postoperative infection, fracture healing time, as well as NRS pain scores, Lysholm knee function scores, and knee range of motion.

View Article and Find Full Text PDF

A 57-year-old man presented with a tibial shaft fracture treated with tibial intramedullary nail fixation and plate and screw fixation for fibular fracture. Two weeks postoperatively, the patient developed skin sloughing with exposed bone and metal at the fracture site. Three weeks postoperatively, a physical examination revealed swelling of the left lateral malleolus and lower leg, a skin defect of approximately 3 × 5 cm at the lower third of the left tibia with an exposed fracture site and hardware in between the fracture fragments.

View Article and Find Full Text PDF

It is unclear whether small plates are needed for augment fixation to provide a more stable mechanical environment in segmental fractures of the tibia treated with intramedullary nail. The purpose of this study was to investigate the efficacy of intramedullary nailing combined with locking plates in the treatment of segmental fractures of the tibia. This study included 41 patients with segmental tibia fractures between January 1, 2018 and January 1, 2023.

View Article and Find Full Text PDF

The acute management of Pilon fractures (ENFORCE) study: a national evaluation of practice.

Ann R Coll Surg Engl

December 2024

Torbay and South Devon NHS Foundation Trust, UK.

Introduction: Pilon fractures are potentially limb-threating injuries. Staged soft tissue damage control is described, but actual practices are unknown. We report a national trainee collaborative evaluating how tibial Pilon fractures are acutely managed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!