Purpose: Patient-specific titanium implants are increasingly used in orbital trauma as a means of achieving improved surgical outcomes as well as decreasing postoperative complications; however, the data to support their use remain limited. The purpose of this study is to compare the complication rates and accuracy of orbital reconstruction using preformed titanium mesh implants and patient-specific implants.

Methods: The authors conducted a retrospective cohort study consisting of patients with orbital floor and/or medial wall fractures treated by reconstruction with either preformed or patient-specific implants from August 1, 2015 to December 31, 2020. The primary predictor variable was the implant type. Outcome variables were the percent volume difference between the reconstructed and uninjured orbital volume and complications. Statistical analysis was performed using Fisher exact test and Wilcoxon rank-sum test.

Results: Of the 85 patients in the study, 73% were male and the average age was 38.7 ± 16.6 years. Sixty-one patients (72%) were treated with preformed implants and 24 (28%) with patient-specific implants. Complications occurred in 8.3% of the patient-specific implant group and 26.2% of the preformed implant group (P = .08). Percent volume difference between the reconstructed and nontraumatized orbit was 4.2% and 6.8% in the patient-specific and preformed implant group, respectively (P = .03).

Conclusions: Patient-specific implants improved orbital volume reconstruction accuracy but did not decrease complications when compared to preformed implants.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joms.2021.12.006DOI Listing

Publication Analysis

Top Keywords

patient-specific implants
16
orbital volume
12
implant group
12
patient-specific
8
decrease complications
8
volume reconstruction
8
reconstruction accuracy
8
reconstruction preformed
8
percent volume
8
volume difference
8

Similar Publications

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

Artificial Intelligence-Guided Inverse Design of Deployable Thermo-Metamaterial Implants.

ACS Appl Mater Interfaces

January 2025

Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.

Current limitations in implant design often lead to trade-offs between minimally invasive surgery and achieving the desired post-implantation functionality. Here, we present an artificial intelligence inverse design paradigm for creating deployable implants as planar and tubular thermal mechanical metamaterials (thermo-metamaterials). These thermo-metamaterial implants exhibit tunable mechanical properties and volume change in response to temperature changes, enabling minimally invasive and personalized surgery.

View Article and Find Full Text PDF

In-stent restenosis represents a major cause of failure of percutaneous coronary intervention with drug-eluting stent implantation. Computational multiscale models have recently emerged as powerful tools for investigating the mechanobiological mechanisms underlying vascular adaptation processes during in-stent restenosis. However, to date, the interplay between intervention-induced inflammation, drug delivery and drug retention has been under-investigated.

View Article and Find Full Text PDF

Objectives: The movement towards personalization of cochlear implantation has continued to generate interest about variabilities in cochlear size. In a recent meta-analysis, Atalay et al. (2022) examined organ of corti length, cochlear lateral wall, and "A" value and found that most covariates, other than congenital sensorineural hearing loss, did not impact cochlear size via these measurements.

View Article and Find Full Text PDF

Design, characterisation, and clinical evaluation of a novel porous Ti-6Al-4V hemipelvic prosthesis based on Voronoi diagram.

Biomater Transl

September 2024

Orthopaedic Research Institute and Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.

Three-dimensional printed Ti-6Al-4V hemipelvic prosthesis has become a current popular method for pelvic defect reconstruction. This paper presents a novel biomimetic hemipelvic prosthesis design that utilises patient-specific anatomical data in conjunction with the Voronoi diagram algorithm. Unlike traditional design methods that rely on fixed, homogeneous unit cell, the Voronoi diagram enables to create imitation of trabecular structure (ITS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!