Objectives: Ultrasound measurement of the optic nerve sheath diameter (ONSD) is a rapid, non-invasive means to indirectly assess intracranial pressure. Previous research has demonstrated the ability of emergency physicians to measure ONSD accurately with bedside ultrasound when compared to CT scan or MRI, however the reliability of this measurement between two or more operators has been called into question (Hassen et al. in J Emerg Med 48:450-457, 2015; Shirodkar et al. in Ind J Crit Care Med 19:466-470, 2015). Given the need for accurate and precise measurement to use this as a screening exam, we sought to determine the inter-rater reliability between ONSD measurements obtained in real time by fellowship-trained emergency ultrasound physicians.
Methods: Three ultrasound fellowship-trained emergency physicians measured bilateral ONSD of 10 healthy volunteers using a high-frequency linear transducer. The physicians were blinded to the other scanners' measurements, and no instructions were given other than to obtain the ONSD. Each sonographer measured the ONSD in real time and it was recorded by a research coordinator. All measurements were recorded in millimeters. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability.
Results: A total of 60 measurements of ONSD were obtained. The average measurement was 4.3 mm (3.83-4.77). Very little variation was found between the three physicians, with a calculated ICC of 0.82 (95% confidence interval 0.63-0.92).
Conclusions: ONSD measurement obtained by ultrasound fellowship-trained emergency medicine physicians is a reliable measurement with a high degree of correlation between scanners.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8748557 | PMC |
http://dx.doi.org/10.1186/s13089-021-00255-1 | DOI Listing |
J Hand Surg Am
January 2025
Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia; Division of Plastic, Reconstructive and Oral Surgery, Children's Hospital of Philadelphia, Philadelphia, PA. Electronic address:
Purpose: Acute hand infections (AHIs) remain a challenge for hand surgeons and represent a condition for which clinical outcomes are considerably affected by social barriers. We previously described the looped Penrose drainage technique, where a drain is sutured to itself in a loop and the outflow tract of egress is maintained, thus obviating the need for large incisions, wound closure, or repeat packing, thereby reducing the follow-up burden. In the face of escalating numbers of socioeconomically vulnerable patients, especially in urban settings, we aimed to characterize the clinical features and outcomes of this technique in an urban population of patients with AHI.
View Article and Find Full Text PDFJ Emerg Med
January 2025
Department of Emergency Medicine, Rutgers New Jersey Medical School, Newark, New Jersey.
Background: Gastrointestinal bleeding (GIB) is a common condition in the emergency department (ED) with high incidence and mortality.
Objectives: Very early risk stratification of GIB patients can sometimes be a challenge. The decision to intubate these patients is multifactorial and requires careful consideration.
Introduction: A chest X-ray (CXR) is the most common imaging investigation performed worldwide. Advances in machine learning and computer vision technologies have led to the development of several artificial intelligence (AI) tools to detect abnormalities on CXRs, which may expand diagnostic support to a wider field of health professionals. There is a paucity of evidence on the impact of AI algorithms in assisting healthcare professionals (other than radiologists) who regularly review CXR images in their daily practice.
View Article and Find Full Text PDFCJEM
January 2025
Department of Emergency Medicine and Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
Objectives: POCUS is a core emergency medicine skill and mainstay of early pregnancy assessment. The ultrasound competency assessment tool was developed as an entrustment-based assessment tool for use by content experts evaluating trainees performing multiple POCUS study types. The objective of this study was to evaluate the scoring and extrapolation inferences of the tool within Kane's validity framework when used to assess trainees performing an early pregnancy POCUS.
View Article and Find Full Text PDFAm J Emerg Med
November 2024
Department of Health Sciences, Cleveland Clinic Akron General, USA. Electronic address:
Introduction: Acute valvular emergencies, a time-sensitive diagnosis, are nearly impossible to diagnose without ultrasound, and missing the diagnosis can significantly impact patient outcomes. Many emergency physicians lack access to echo technicians and may be uncomfortable performing the ultrasound themselves. Approaching the paucity of review articles, none of which are focused for the emergency physician, can be quite daunting, even for those with extensive ultrasound training.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!