Described herein are the cases of 2 patients who underwent bilateral femtosecond-assisted laser in situ keratomileusis (FS LASIK) surgery and subsequently developed unilateral postLASIK ectasia. The fellow eye of both patients was topographically normal, their visual acuity was 20/20, and the patients had no visual symptoms. However, a biomechanical assessment using the Corvis ST tonometer (Oculus Optikgerate GmbH; Wetzlar, Germany) revealed remarkable weakness not only in the ectatic eyes, but also in the fellow eye. Arrangements were made to perform corneal crosslinking for the eyes with manifest ectasia and close follow-up of the fellow eyes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651025 | PMC |
http://dx.doi.org/10.14744/bej.2021.32559 | DOI Listing |
Adv Sci (Weinh)
January 2025
School of Pharmaceutical Sciences, Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases, Zhengzhou University, Zhengzhou, 450001, China.
Although cytotoxic T lymphocytes (CTLs) activation combined with programmed cell death-1 (PD-1)/programmed cell death ligand-1 (PD-L1) axis blockade have emerged as an effective strategy to improve immunotherapeutic potency, it remains challenging to realize the spatiotemporal synergy of these two components. Herein, the study reports an engineered bacterial-based delivery system that can simultaneously promote CTLs infiltration and control PD-L1 binding protein (PD-L1 trap) release on demand at tumor site. The drug release button of this tumor targeting system is the specific temperature, which is accomplished by dual-modified melanin nanoparticles with photothermal conversion capacity on the engineered bacterial.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
Quantum Nano Centre, Department of Chemical Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Laser conversion of commercial polymers to laser-induced graphene (LIG) using inexpensive and accessible CO lasers has enabled the rapid prototyping of promising electronic and electrochemical devices. Frequently used to pattern interdigitated supercapacitors, few approaches have been developed to pattern batteries-in particular, full cells. Herein, we report an LIG-based approach to a planar, interdigitated Li-S battery.
View Article and Find Full Text PDFAppl Spectrosc
January 2025
School of Mathematics Physics and Finance, Anhui Polytechnic University, Wuhu, China.
A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH) and acetylene (CH). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H) filter algorithm to reduce the system noise.
View Article and Find Full Text PDFCureus
December 2024
Department of Ophthalmology, UT Southwestern Medical Center, Dallas, USA.
An 83-year-old male with a history of radial keratotomy and laser-assisted in situ keratomileusis (LASIK) presented with symptoms of a non-resolving corneal ulcer in the right eye that had been present for five months. The patient was treated with antibacterial, antiviral, and antifungal medications over that period, with multiple recurrences that prompted referral to our tertiary center for management. Following a 48-hour cessation of all medications, a corneal biopsy was performed which grew .
View Article and Find Full Text PDFVascular
January 2025
Division of Vascular Surgery, Medical University of South Carolina, Charleston, SC, USA.
Objectives: Mal-deployment of the thoracic endovascular aortic repair (TEVAR) stent graft during a frozen elephant trunk (FET) procedure for an acute type A aortic dissection (ATAAD) leads to devastating complications. We report a hemiarch replacement with TEVAR stent graft covering the aortic arch vessels salvaged through an endovascular approach.
Methods: A 69-year-old man with ATAAD in 2018, status post-hemiarch repair with TEVAR, presented in 2023 with progressive dizziness/syncope and lower extremity hypertension with inability to tolerate anti-hypertensives.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!