A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Critical Analysis of Lateral Versus Central Endpoint in Distal Tibia Nailing: Does It Affect Alignment? | LitMetric

Objectives: To evaluate the effect of a traditional "center-center" end point for distal tibia nailing in comparison with a lateral-of-center end point on fracture malalignment in a cadaver model.

Methods: Nine matched pairs of human cadaveric lower-extremity specimens were used to model the effect of nail end point on fracture alignment in extra-articular distal tibia fractures. After simulation of the fracture through a standardized osteotomy, 1 member of each pair was fixed with an intramedullary nail using a "center-center" end point, whereas a lateral-of-center end point was used for the other member of the pair. Specimens were stripped of soft tissue, and digital calipers were used to measure fracture translation and gap medially, laterally, anteriorly, and posteriorly. Coronal plane angulation at each fracture was measured on the final mortise image.

Results: The average coronal angulation was 7.0 degrees of valgus (with a SD of 4.1) in central-end point specimens versus 0.2 degrees of valgus (SD = 1.5) in lateral-end point specimens ( P < 0.001). Lateral-end point specimens also demonstrated significantly less fracture gap medially (mean 0.2 vs. 3.1 mm for central-end point specimens, P < 0.001), anteriorly (mean 0.1 vs. 1.3 mm, P = 0.003), and posteriorly (mean 0.3 vs. 2.2 mm, P = 0.003). Lateral-end point specimens also showed less lateral translation (mean 0.6 vs. 1.6 mm, P = 0.006).

Conclusions: Lateral-of-center nail end points may help surgeons restore native alignment in extra-articular distal tibia fractures and avoid valgus malalignment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10371388PMC
http://dx.doi.org/10.1097/BOT.0000000000002345DOI Listing

Publication Analysis

Top Keywords

point specimens
20
distal tibia
16
lateral-end point
12
point
10
tibia nailing
8
"center-center" point
8
lateral-of-center point
8
point fracture
8
alignment extra-articular
8
extra-articular distal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!