Objectives: To investigate the volumetric and vertical loss of occlusal splints manufactured by conventional (heat-cure), subtractive (CAD/CAM) and additive (3D-printing) methods.
Methods: Six occlusal splint materials were investigated (n = 126), using three manufacturing methods: heat-cured, CAD/CAM and 3D-printed built-in three different printing angles (0°,45°and 90°). Block-on-ring wear testing was performed with extracted human molars as the antagonist. All samples were tested with an applied force of 49N at 1 Hz and 60RPM in artificial saliva at 37 °C for six and 12 months. Scanning electron microscopy images were analysed to evaluate the wear on the tooth enamel and in the splint material. Volumetric and vertical wear loss were statistically analysed.
Results: The lowest volumetric and vertical loss was observed in CAD-CAM materials (6.44 ± 1.77 mm and 48.3 ± 7.14 μm) with no statistical significance to the heat-cured material (17.22 ± 9.23 mm and 148 ± 121.1 μm) after 12 months (p < 0.172). The mean volumetric loss of 3D printed materials ranged from 0.25 ± 0.15 mm to 0.29 ± 0.1 4mm with no statistical difference, whereas, the differences in vertical loss from 131.63 ± 44.1 μm to 493 ± 79.19 μm were statistically significant (p < 0.001). The highest vertical loss was observed in the KeySplint Soft 3D printed at 90° (385.35 ± 82.37 μm), whereas FreePrint Splint 2.0 with a build angle of 0° had the highest volumetric loss (204.59 ± 25.67 mm).
Conclusion: CAD-CAM material had the highest wear resistance followed by heat-cured material.KeySplint Soft and FreePrint Splint 2.0 3D printed materials would be preferred for patients that do not have severe bruxing episodes. No significant wear of human enamel after six and 12 months was observed under SEM for any tested materials.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmbbm.2021.105053 | DOI Listing |
J Prosthodont Res
January 2025
Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen.
Purpose: This systematic review evaluated the effect of different printing orientations on the physical-mechanical properties and accuracy of resin denture bases and related specimens.
Study Selection: Utilizing PRISMA 2020 guidelines, a comprehensive search of PubMed, Web of Science, Cochrane, and Scopus databases was conducted until June 2024. Included studies examined the accuracy, volumetric changes, and mechanical or physical properties of 3D-printed denture bases in various orientations.
Small
January 2025
School of Chemical, Biological and Battery Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, Republic of Korea.
Seawater batteries (SWBs) have emerged as a next-generation battery technology that does not rely on lithium, a limited resource essential for lithium-ion batteries. Instead, SWBs utilize abundant sodium from seawater, offering a sustainable alternative to conventional battery technologies. Previous studies have demonstrated the feasibility of achieving high energy densities in SWB anodes using vertically aligned electrodes.
View Article and Find Full Text PDFWorld J Radiol
December 2024
Department of Radiology, Kantonsspital Baden, The Affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland.
Background: The auricle, or auricula, defines the visible boundaries of the external ear and is essential in forensic investigations, including facial reconstruction and human remains identification. Beyond its forensic significance, auricular morphology attracts interest from various fields, such as medicine and industry. The size of the ears is culturally associated with health and longevity, while surgical techniques for ear reconstruction address both congenital and aesthetic concerns.
View Article and Find Full Text PDFAm J Orthod Dentofacial Orthop
January 2025
Department of Orthodontics, Faculty of Dentistry, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China. Electronic address:
Introduction: This study aimed to assess the root resorption and alveolar bone changes of maxillary incisors volumetrically and 3-dimensionally in patients with Class II Division 1 malocclusion who underwent treatments involving the extraction of 4 first premolars with conventional fixed appliances (FAs) vs clear aligners (CAs).
Methods: A total of 320 maxillary incisors from 80 patients were assessed and divided into 2 groups (FAs and CAs), each possessing similar baseline characteristics. Pretreatment and posttreatment cone-beam computed tomography scans were used to analyze linear and volumetric orthodontically induced inflammatory root resorption, alveolar bone thickness (ABT), alveolar bone height (ABH), as well as anteroposterior and vertical movements of maxillary incisors.
J Prosthodont Res
January 2025
Substitutive Dental Science Department, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia.
Purpose: This systematic review aims to assess the impact of different 3D printing orientations on the physico-mechanical properties, volumetric change, and accuracy of additively manufactured ceramic specimens, as well as their restorations.
Study Selection: The web database containing records for building orientation of 3D-printed ceramics until January 2024 was searched, with no language limitations. PRISMA 2020 guidelines were followed, and the risk of bias was evaluated using the modified CONSORT checklist for laboratory studies on dental materials.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!