Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, And Key Laboratory of Luminescent and Real-Time Anal. Chem. (Southwest University), Chongqing Science and Technology Bureau, College of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, PR China. Electronic address:

Published: April 2022

MicroRNAs involved in tumor-related tissues at abnormal expression level present tremendous potential in the early diagnosis of cancers. However, their intrinsic shortcomings, for instance, low abundance and high sequence homology, make it challengeable to quantify them with high sensitivity and selectivity. Herein, a highly sensitive platform with great specificity was developed for microRNA-21 based on the produced-I triggered chemical etching of gold nanorods to a smaller size, resulting in a significant blue shift and a great intensity decrease in the localized surface plasmon resonance (LSPR) scattering. The synergism of strand displacement and enzymatic reaction enabled the proposed strategy with a high sensitivity and selectivity toward microRNA-21 in a dynamic range from 0.1 to 10,000 pM and a low limit of detection of 71.22 fM (3σ/k) by dark-field microscope. Additionally, the remarkable discrimination of single nucleotide difference suggested the superior selectivity towards microRNA-21, which presented a satisfactory recovery in human serum samples. The proposed plasmon platform could also serve as a universal and sensitive detection of cancer biomarkers, presenting the amusing application prospects in the early diagnosis of various cancers by adapting the corresponding nucleic acid sequences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2021.113942DOI Listing

Publication Analysis

Top Keywords

highly sensitive
8
sensitive detection
8
chemical etching
8
etching gold
8
gold nanorods
8
dark-field microscope
8
early diagnosis
8
diagnosis cancers
8
high sensitivity
8
sensitivity selectivity
8

Similar Publications

Background: Neuroendocrine tumors primarily consist of endocrine cells commonly located in neural tissue and the endocrine system. Primary neuroendocrine neoplasms of the breast are highly heterogeneous tumors characterized by a diverse cell population. Their rarity in the breast poses considerable challenges in studying their pathogenesis and developing effective treatments.

View Article and Find Full Text PDF

Strongylus vulgaris, a devastating parasitic nematode in equids, causes life-threatening verminous aneurysms that are challenging to diagnose early. This study pioneered integrating nanotechnology into an indirect enzyme-linked immunosorbent assay (i-ELISA) system to enhance the sensitivity and specificity for detecting S. vulgaris larval antigens in equine serum samples, with PCR confirmation of the species.

View Article and Find Full Text PDF

Gene expression profiling for the diagnosis of male breast cancer.

BMC Cancer

December 2024

Department of Pathology, Fudan University Shanghai Cancer Center, and Shanghai Key Laboratory of Medical Epigenetics, International Co-laboratory of Medical Epigenetics and Metabolism, Institutes of Biomedical Sciences, Shanghai Medical College, Fudan University, Shanghai, China.

Background: Male breast cancer (MBC) is a rare malignancy, but its global incidence has shown a notable increase in recent decades. Factors such as limited health literacy, inadequate health education, and reluctance to seek medical attention contribute to the late-stage diagnosis of most MBC patients. Consequently, there is an urgent need for a highly specific and sensitive diagnostic approach to MBC.

View Article and Find Full Text PDF

In the current scenario, decision-making models are essential for analyzing real-world problems. To address the dynamic nature of these problems, fuzzy decision-making models have been proposed by various researchers. However, an advanced technique is needed to assess uncertainty in real-time complex situations.

View Article and Find Full Text PDF

pH sensing technology is pivotal for monitoring aquatic ecosystems and diagnosing human health conditions. Indium-gallium-zinc oxide electrolyte-gated thin-film transistors (IGZO EGTFTs) are highly regarded as ion-sensing devices due to the pH-dependent surface chemistry of their sensing membranes. However, applying EGTFT-based pH sensors in complex biofluids containing diverse charged species poses challenges due to ion interference and inherently low sensitivity constrained by the Nernst limit.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!