Development of haptic interfaces to enrich augmented and virtual reality with the sense of touch is the next frontier for technological advancement of these systems. Among available technologies, electrotactile stimulation enables design of high-density interfaces that can provide natural-like sensation of touch in interaction with virtual objects. The present study investigates the human perception of electrotactile sensations on fingertips, focusing on the sensation localization in function of the size and position of reference electrode. Ten healthy subjects participated in the study, with the task to mark the sensations elicited by stimulating the index fingertip using an 8-pad electrode. The test systematically explored several configurations of the active (position) and reference (position and size) electrode pads. The results indicated that there was a spreading of perceived sensations across the fingertip, but that they were mostly localized below the active pad. The position and size of the reference electrode were shown to affect the location of the perceived sensations, which can potentially be exploited as an additional parameter to modulate the feedback. The present study demonstrates that the fingertip is a promising target for the delivery of high-resolution feedback.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TOH.2022.3141187DOI Listing

Publication Analysis

Top Keywords

position reference
12
reference electrode
12
size position
8
electrotactile stimulation
8
position size
8
perceived sensations
8
position
5
electrode
5
impact size
4
reference
4

Similar Publications

To accurately model and validate the 6 MV Elekta Compactlinear accelerator using the Geant4 Application for Tomographic Emission (GATE). In particular, this study focuses on the precise calibration and validation of critical parameters, including jaw collimator positioning, electron source nominal energy, flattening filter geometry, and electron source spot size, which are often not provided in technical documentation. Methods: Simulation of the Elekta Compact6 MV linear accelerator was performed using the Geant4 Application for Tomographic Emission (GATE) v.

View Article and Find Full Text PDF

In weightlifting, quantitative kinematic analysis is essential for evaluating snatch performance. While marker-based (MB) approaches are commonly used, they are impractical for training or competitions. Markerless video-based (VB) systems utilizing deep learning-based pose estimation algorithms could address this issue.

View Article and Find Full Text PDF

Virtual patients with substance use disorders in healthcare professional education: a scoping review.

Can Med Educ J

December 2024

Department of Community Health Sciences, Addiction Studies and Research Programs, Université de Sherbrooke, Quebec, Canada.

Background And Objective: Virtual patient simulations are cost-effective methods for training health professionals. Yet, this teaching method is rarely used with clinicians who work or plan on working with people with substance use disorders. This scoping review summarizes the current state of the literature concerning virtual substance use disorder patient simulations in health professionals' training and provides suggestions for future directions.

View Article and Find Full Text PDF

%diag_test: a generic SAS macro for evaluating diagnostic accuracy measures for multiple diagnostic tests.

BMC Med Inform Decis Mak

January 2025

Institute of Mathematical Sciences Centre for Health Analytics and Modelling (CHaM), Strathmore University, Nairobi, Kenya.

Background: Measures of diagnostic test accuracy provide evidence of how well a test correctly identifies or rules-out disease. Commonly used diagnostic accuracy measures (DAMs) include sensitivity and specificity, predictive values, likelihood ratios, area under the receiver operator characteristic curve (AUROC), area under precision-recall curves (AUPRC), diagnostic effectiveness (accuracy), disease prevalence, and diagnostic odds ratio (DOR) etc. Most available analysis tools perform accuracy testing for a single diagnostic test using summarized data.

View Article and Find Full Text PDF

ECG challenge: Intermittent wide QRS complexes in heterotaxy syndrome.

J Electrocardiol

January 2025

Division of Pediatric Cardiology, Department of Pediatrics, Medical University Graz, Graz, Austria.

We report wide QRS complexes appearing in conjunction with prolonged R-R intervals in a 5- year old patient with situs ambiguous and mirror image dextrocardia, who had undergone ASD and VSD closure at of the age of one. We present differential diagnoses of intermittent spontaneous QRS widening and refer to ECG lead positioning in mirror image dextrocardia patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!