A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

ASSESSMENT OF OCCUPATIONAL RADIATION DOSE FROM CAMERA MODEL INTRAORAL HANDHELD X-RAY DEVICE WITHOUT STRAY RADIATION PROTECTION SHIELD. | LitMetric

ASSESSMENT OF OCCUPATIONAL RADIATION DOSE FROM CAMERA MODEL INTRAORAL HANDHELD X-RAY DEVICE WITHOUT STRAY RADIATION PROTECTION SHIELD.

Radiat Prot Dosimetry

Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran 1983969411, Iran.

Published: February 2022

The aim of this study was to assess the occupational exposure from portable X-ray device without stray radiation protection shield measured using thermoluminescent dosemeters (TLDs). A total of 108 intraoral periapical radiographies of six sextants were performed. The TLDs were located on right index finger and left palm, between the pupils of the eyes at the edges of the Nasion point, Manubrium of Sternum bone and genital area. The detected mean doses per procedure were 70, 99, 60, 51, 51 and 58 μSv in the right finger, left palm, level of the Nasion point, under left clavicle, above the sternum manubrium and at the gonad area, respectively. Maximum number of radiographic images that the operator is allowed to perform depends on eye exposure and in accordance with International Commission on Radiological Protection is 0.16 (0.12-0.23) per hour or 1.28 (0.96-1.84) per day.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncab173DOI Listing

Publication Analysis

Top Keywords

x-ray device
8
device stray
8
stray radiation
8
radiation protection
8
protection shield
8
finger left
8
left palm
8
nasion point
8
assessment occupational
4
occupational radiation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!