The turbo spin-echo (TSE) sequence is widely used for musculoskeletal (MSK) imaging; however, its acquisition speed is limited and can be easily affected by motion artifacts. We aimed to evaluate whether the use of a simultaneous multi-slice TSE (SMS-TSE) sequence can accelerate MSK imaging while maintaining image quality when compared with the routine TSE sequence. We prospectively enrolled 71 patients [mean age, 37.43 ± 12.56 (range, 20-67) years], including 37 men and 34 women, to undergo TSE and SMS sequences. The total scanning times for the wrist, ankle and knee joint with routine sequence were 14.92, 13.97, and 13.48 min, respectively. For the SMS-TSE sequence, they were 7.52, 7.20, and 6.87 min. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured. Three experienced MSK imaging radiologists qualitatively evaluated the image quality of bone texture, cartilage, tendons, ligament, meniscus, and artifact using a 5-point evaluation system, and the diagnostic performance of the SMS-TSE sequences was evaluated. Compared with the routine TSE sequences, the scanning time was lower by 49.60, 48.46, and 49.04% using SMS-TSE sequences for the wrist, ankle, and knee joints, respectively. For the SNR comparison, the SMS-TSE sequences were significantly higher than the routine TSE sequence for wrist (except for Axial-T2WI-FS), ankle, and knee joint MR imaging ( < 0.05), but no statistical significance was obtained for the CNR measurement ( > 0.05, except for Sag-PDWI-FS in ankle joint). For the wrist joint, the diagnostic sensitivity, specificity, and accuracy were 88.24, 100, and 92%. For the ankle joint, they were 100, 75, and 93.33%. For the knee joint, they were 87.50, 85.71, and 87.10%. The use of the SMS-TSE sequence in the wrist, ankle, and knee joints can significantly reduce the scanning time and show similar image quality when compared with the routine TSE sequence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8724040PMC
http://dx.doi.org/10.3389/fphys.2021.759888DOI Listing

Publication Analysis

Top Keywords

tse sequence
16
routine tse
16
ankle knee
16
turbo spin-echo
12
msk imaging
12
sms-tse sequence
12
image quality
12
compared routine
12
wrist ankle
12
knee joint
12

Similar Publications

Background And Objective: Radiosurgery can serve as a primary, adjuvant, or salvage treatment modality for cavernous sinus tumors (CST), providing high tumor control. However, particularly with cavernous sinus expansion, there may be insufficient distance from the optic apparatus to perform radiosurgery safely. The internal carotid artery adjacent to the distal dural ring (ICAddr), when enhancing similarly to the CST, can be difficult to delineate, and can lead to over-contouring of target volume near the optic nerve and therefore increasing the risk of radiation-induced optic toxicity.

View Article and Find Full Text PDF

Objectives: Brain metastases are the most common intracranial malignancy in adults, and their detection is crucial for treatment planning. Post-contrast 3D T1 gradient-recalled echo (GRE) sequences are commonly used for this purpose, but contrast-enhanced 3D T1 turbo spin-echo (TSE) sequences with motion-sensitized driven-equilibrium (MSDE) technique ("black blood") may offer improved detection. This study aimed to compare the effectiveness of contrast-enhanced 3D black blood sequences to standard 3D T1 GRE sequences in detecting brain metastases on a 1.

View Article and Find Full Text PDF

Compressed SENSE acceleration factor influence on magnetic resonance image quality in patients with endometrial cancer.

Phys Med

January 2025

Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovića 3, 21000 Novi Sad, Serbia. Electronic address:

Objectives: To investigate the impact of compressed sensing - sensitivity encoding (CS-SENSE) acceleration factor on the diagnostic performance of magnetic resonance imaging (MRI) within standard female pelvis protocol in patients with endometrial cancer.

Methods: T2-weighted turbo spin echo (TSE) sequence from standard female pelvic MRI protocol was chosen due to its long acquisition time and essential role in the evaluation of morphological characteristics of the female pelvic anatomical structures. Fully sampled reference scans and multiple prospectively 2x to 5x under-sampled CS-SENSE scans were acquired.

View Article and Find Full Text PDF

Aims: To describe the imaging features of patients presenting with soft tissue masses and a provisional diagnosis of soft tissue tumours, for whom biopsy confirmed the presence of necrotising granulomata consistent with tuberculoma.

Material And Methods: A review of the histopathology database for patients who had a diagnosis of necrotising granulomata in nonspinal sites. Patients with bone and joint-based pathology were excluded.

View Article and Find Full Text PDF

Circulating Adenoid Cystic Carcinoma associated MYB transcripts enable rapid and sensitive detection of metastatic disease in blood liquid biopsies.

J Liq Biopsy

December 2024

Dr. Nasser Ibrahim Al-Rashid Orbital Vision Research Center, Bascom Palmer Eye Institute, Miller School of Medicine, University of Miami, Miami, FL 33136, USA.

Adenoid cystic carcinoma (ACC) is a rare and lethal malignancy that originates in secretory glands of the head and neck. A prominent molecular feature of ACC is the overexpression of the proto-oncogene MYB. ACC has a poor long-term survival due to its high propensity for recurrence and protracted metastasis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!