Background: Fabry disease (FD) is a treatable X-linked condition leading to progressive cardiac disease, arrhythmia and premature death. We aimed to increase awareness of the arrhythmogenicity of Fabry cardiomyopathy, by comparing device usage in patients with Fabry cardiomyopathy and sarcomeric HCM. All Fabry patients with an implantable cardioverter defibrillator (ICD) implanted in the UK over a 17 year period were included. A comparator group of HCM patients, with primary prevention ICD implantation, were captured from a regional registry database.

Results: Indications for ICD in FD varied with 72% implanted for primary prevention based on multiple potential risk factors. In FD and HCM primary prevention devices, arrhythmia occurred more frequently in FD over shorter follow-up (HR 4.2, p < 0.001). VT requiring therapy was more common in FD (HR 4.5, p = 0.002). Immediate shock therapy for sustained VT was also more common (HR 2.5, p < 0.001). There was a greater burden of AF needing anticoagulation and NSVT in FD (AF: HR 6.2, p = 0.004, NSVT: HR 3.1, p < 0.001).

Conclusion: This study demonstrates arrhythmia burden and ICD usage in FD is high, suggesting that Fabry cardiomyopathy may be more 'arrhythmogenic' than previously thought. Existing risk models cannot be mutually applicable and further research is needed to provide clarity in managing Fabry patients with cardiac involvement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8734227PMC
http://dx.doi.org/10.1186/s13023-021-02133-4DOI Listing

Publication Analysis

Top Keywords

primary prevention
12
device usage
8
fabry cardiomyopathy
8
fabry
5
cardiac device
4
device implantation
4
implantation device
4
usage fabry
4
fabry hypertrophic
4
hypertrophic cardiomyopathy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!