Air pollution has been associated with childhood neurodevelopment. However, the role of indoor air pollution, especially volatile organic compounds (VOCs), on childhood neurodevelopment has been poorly explored to date. We investigated the association between indoor air pollutants and childhood neurodevelopment in 5,017 randomly selected children from the Japan Environment and Children's Study. When the participants reached 1.5 and 3 years of age, they were followed up with home visits and neurodevelopmental tests using the Ages and Stages Questionnaire (ASQ). At both ages, we collected indoor air samples for 1 week and measured 13 indoor air pollutants: particulate matter with an aerodynamic diameter of ≤2.5 μm, ozone, nitrogen dioxide, sulfur dioxide, and nine VOCs. The associations between air pollutants and ASQ scores were estimated using linear mixed effects models and weighted quantile sum regressions (WQS) at each age separately. Stratified analysis by sex was conducted. Exposure to m,p-xylene at the age of 3 was associated with lower communication, fine motor, and overall ASQ scores (coefficients: -0.18 [99% confidence intervals (CI): -0.35, -0.02], -0.23 [99 %CI: -0.43, -0.03], and - 0.72 [99 %CI: -1.41, -0.04] per 1 µg/m increase, respectively). Exposure to o-xylene at the age of 3 was associated with lower communication, gross motor, fine motor, and overall ASQ scores (coefficients: -0.48 [99 %CI: -0.90, -0.07], -0.45 [99 %CI: -0.78, -0.13], -0.65 [99 %CI: -1.14, -0.16], and -2.15 [99 %CI: -3.83, -0.47] per 1 µg/m increase, respectively). The WQS index was associated with lower gross motor ASQ scores at the age of 3 (coefficient: -0.27 [95 %CI: -0.51, -0.03] for one-unit WQS index increases), which was attributed to benzene (33.96%), toluene (26.02%), o-xylene (13.62%), and ethylbenzene (9.83%). Stratified analysis showed similar results. Although further investigations are required, our results suggest an association of neurodevelopmental delays with indoor low-level exposure to m,p-xylene and o-xylene in early life.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.envint.2021.107004 | DOI Listing |
Interest in carbon dioxide (CO) sensors is growing rapidly due to the increasing awareness of the link between air quality and health. Indoor, high CO levels signal poor ventilation, and outdoor the burning of fossil fuels and its associated pollution. CO gas sensors based on integrated optical waveguides are a promising solution due to their excellent gas sensing selectivity, compact size, and potential for mass manufacturing large volumes at low cost.
View Article and Find Full Text PDFSci Total Environ
January 2025
Department of Environmental Protection, Faculty of Geology, Geophysics, and Environmental Protection, AGH University of Krakow, Al. Mickiewicza 30, 30-059 Krakow, Poland.
Formaldehyde is considered as a significant contaminant. This study aimed to perform comprehensive research with systematic review, health risk estimation, meta-analysis, and Monte Carlo simulation to evaluate exposure to formaldehyde at different seasons of the year in various indoor environments. A systematic literature review was initially performed.
View Article and Find Full Text PDFCurr Environ Health Rep
January 2025
Center for Public Health and Environmental Assessment, United States Environmental Protection Agency, 104 Mason Farm Rd., Chapel Hill, NC, 27514, USA.
Purpose Of Review: A major contributor to household air pollution (HAP) in sub-Saharan Africa (SSA) is unclean cooking fuel. Improved cookstove technology (ICT) interventions have been promoted as a solution, but their impacts on health are unclear. Our aim is to conduct a systematic review to explore the impacts of ICT interventions on health outcomes in SSA.
View Article and Find Full Text PDFRespir Res
January 2025
Center for Genes, Environment, and Health, National Jewish Health, Denver, CO, USA.
Background: Air pollution is associated with poor asthma outcomes in children. However, most studies focus on ambient or indoor monitor pollution levels. Few studies evaluate breathing zone exposures, which may be more consequential for asthma outcomes.
View Article and Find Full Text PDFAppl Physiol Nutr Metab
January 2025
University of Ottawa, Ottawa, Canada.
We evaluated enterocyte damage (IFABP), microbial translocation (sCD14), and inflammatory responses (TNF-α, IL-6, CRP) in 16 older adults (66-78 years) during 8 hours rest in conditions simulating homes maintained at 22°C (control), the 26°C indoor temperature upper limit proposed by health agencies, and homes without air-conditioning during heatwaves (31°C, 36°C). Relative to 22°C, IFABP was elevated ~181 pg/mL after exposure to 31°C (P=0.07), and by ~378 pg/mL (P<0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!