To compare the differences of hip offset and rotation center reconstruction between robot-assisted and manual total hip arthroplasty (THA). Patients underwent robot-assisted and manual THA from May to September of 2020 in the First Affiliated Hospital of Chongqing Medical University were enrolled in this study. The patients included 27 patients (28 hips) in robot-assisted THA (rTHA) group and 29 patients (31 hips) in manual THA (mTHA) group. In rTHA group, there were 16 males and 11 females, with a mean age of (59±13) years. In mTHA group, there were 18 males and 11 females, with a mean age of (63±14) years. Basic information, including gender, age, body mass index (BMI), diagnosis and functional scoring etc, were recorded. In rTHA group, Mako robot system was used for preoperative planning, intraoperative real-time location and navigation. In mTHA group, traditional preoperative template design and surgical procedure were carried out. Operation time and functional scoring were compared postoperatively. Femoral offset, acetabular offset, global offset, rotation center changes in vertical and horizontal directions were measured on pelvis X-ray and analyzed. The correlation between intraoperative feedback of global offset change in robot system and postoperative measured global offset were analyzed. Operation time in rTHA group was (80±10) min, which was statistically longer than that in mTHA group ((58±18) min, <0.001). With 6 months' follow-up, the Harris scoring in rTHA group was 94.9±2.8, which was statistically higher than that in mTHA group (93.1±2.8, =0.017), however there was no statistic difference in WOMAC scoring between rTHA and mTHA group (7.0±3.8 vs 7.1±2.4, =0.840). Absolute global offset change within 5 mm, 5-10 mm and lager than 10 mm were 71.4%(20/28), 28.6%(8/28) and 0 in rTHA group, which were 45.2%(14/31), 29.0%(9/31) and 25.8%(8/31) in mTHA group (all <0.05). A positive relation was found between intraoperative feedback of global offset change in robot system and postoperative measured global offset in rTHA group (=0.77, <0.001). It was found that rotation center changes concentrated in outer upper quadrant in both groups, and rotation center change in rTHA group concentrated mainly in the area less than 10 mm, however, rotation center change in mTHA group was more dispersive compared with rTHA group. rTHA may accurately reconstruct hip offset and rotation center, intraoperation feedback of global offset change may be an effective reference.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3760/cma.j.cn112137-20210804-01737 | DOI Listing |
Bone Jt Open
January 2025
Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan.
Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.
Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.
SICOT J
December 2024
The Hazeley Academy, Emperor Drive, Hazeley, Milton Keynes, MK8 0PT, United Kingdom.
Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).
Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).
Adv Orthop
October 2024
Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark.
J Bone Joint Surg Am
December 2024
Department of Orthopaedic Surgery, Southern California Permanente Medical Group, Harbor City, California.
Background: The increased availability of dual-mobility acetabular constructs (DMCs) provides surgeons with a newer option to increase the effective femoral head size in revision total hip arthroplasty (rTHA). We sought to evaluate risks of re-revision and prosthetic dislocation following rTHA involving a DMC compared with other articulations.
Methods: A cohort study was conducted using data from a U.
J Clin Med
September 2024
Orthopedics-Traumatology Department, Faculty of Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!