[Comparison of hip offset and rotation center reconstruction between robot-assisted and manual total hip arthroplasty].

Zhonghua Yi Xue Za Zhi

Department of Orthopedics, the First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, Chongqing 400016, China.

Published: January 2022

AI Article Synopsis

Article Abstract

To compare the differences of hip offset and rotation center reconstruction between robot-assisted and manual total hip arthroplasty (THA). Patients underwent robot-assisted and manual THA from May to September of 2020 in the First Affiliated Hospital of Chongqing Medical University were enrolled in this study. The patients included 27 patients (28 hips) in robot-assisted THA (rTHA) group and 29 patients (31 hips) in manual THA (mTHA) group. In rTHA group, there were 16 males and 11 females, with a mean age of (59±13) years. In mTHA group, there were 18 males and 11 females, with a mean age of (63±14) years. Basic information, including gender, age, body mass index (BMI), diagnosis and functional scoring etc, were recorded. In rTHA group, Mako robot system was used for preoperative planning, intraoperative real-time location and navigation. In mTHA group, traditional preoperative template design and surgical procedure were carried out. Operation time and functional scoring were compared postoperatively. Femoral offset, acetabular offset, global offset, rotation center changes in vertical and horizontal directions were measured on pelvis X-ray and analyzed. The correlation between intraoperative feedback of global offset change in robot system and postoperative measured global offset were analyzed. Operation time in rTHA group was (80±10) min, which was statistically longer than that in mTHA group ((58±18) min, <0.001). With 6 months' follow-up, the Harris scoring in rTHA group was 94.9±2.8, which was statistically higher than that in mTHA group (93.1±2.8, =0.017), however there was no statistic difference in WOMAC scoring between rTHA and mTHA group (7.0±3.8 vs 7.1±2.4, =0.840). Absolute global offset change within 5 mm, 5-10 mm and lager than 10 mm were 71.4%(20/28), 28.6%(8/28) and 0 in rTHA group, which were 45.2%(14/31), 29.0%(9/31) and 25.8%(8/31) in mTHA group (all <0.05). A positive relation was found between intraoperative feedback of global offset change in robot system and postoperative measured global offset in rTHA group (=0.77, <0.001). It was found that rotation center changes concentrated in outer upper quadrant in both groups, and rotation center change in rTHA group concentrated mainly in the area less than 10 mm, however, rotation center change in mTHA group was more dispersive compared with rTHA group. rTHA may accurately reconstruct hip offset and rotation center, intraoperation feedback of global offset change may be an effective reference.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112137-20210804-01737DOI Listing

Publication Analysis

Top Keywords

rtha group
16
mtha group
16
offset rotation
12
rotation center
12
robot-assisted manual
12
global offset
12
hip offset
8
center reconstruction
8
reconstruction robot-assisted
8
manual total
8

Similar Publications

Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.

Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.

View Article and Find Full Text PDF

Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).

Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).

View Article and Find Full Text PDF
Article Synopsis
  • Revision total hip arthroplasty (rTHA) is complex, particularly with significant bone loss affecting implant stability, and this study focused on evaluating outcomes using an uncemented modular implant design in 100 patients.
  • Out of the 101 hips analyzed, 51 had lower-grade bone defects (Paprosky types I-II) and 50 were more severe (types III-IV), with a follow-up averaging 5.8 years, assessing implant survival and clinical outcomes using various scoring measures.
  • The findings revealed a high 5-year implant survival rate of 95%, with successful osseointegration in all hips and no significant subsidence; however, some complications occurred, including dislocations and fractures, but overall
View Article and Find Full Text PDF

Background: The increased availability of dual-mobility acetabular constructs (DMCs) provides surgeons with a newer option to increase the effective femoral head size in revision total hip arthroplasty (rTHA). We sought to evaluate risks of re-revision and prosthetic dislocation following rTHA involving a DMC compared with other articulations.

Methods: A cohort study was conducted using data from a U.

View Article and Find Full Text PDF

Role of Serum Biomarkers in Differentiating Periprosthetic Joint Infections from Aseptic Failures after Total Hip Arthroplasties.

J Clin Med

September 2024

Orthopedics-Traumatology Department, Faculty of Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania.

Article Synopsis
  • Periprosthetic joint infection (PJI) is a serious complication following joint replacement surgeries and accurately diagnosing it is difficult; this study aims to evaluate serum biomarkers for their effectiveness in diagnosing PJI in patients after total hip arthroplasties (THA).
  • The study analyzed 77 patients who underwent revision total hip arthroplasties (rTHA) from January 2019 to December 2023, dividing them into groups with septic complications and aseptic failures, revealing significant differences in several blood markers.
  • The research found that biomarkers like the systemic inflammation index (SII) and neutrophil lymphocyte ratio (NLR) showed high sensitivity but relatively low specificity
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!