A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Trace level determination of eleven nervous system-active pharmaceutical ingredients by switchable solvent-based liquid-phase microextraction and gas chromatography-mass spectrometry with matrix matching calibration strategy. | LitMetric

This study utilized switchable solvent liquid-phase microextraction (SS-LPME) to enrich eleven nervous system active pharmaceutical ingredients (APIs) from aqueous samples for their determination at trace levels by gas chromatography mass spectrometry. The analytes selected for the study included APIs utilized in antidepressant, antipsychotic, antiepileptic, and anti-dementia drugs. Parameters of the microextraction method including switchable solvent volume, concentration and volume of the trigger agent (sodium hydroxide), and sample agitation period were optimized univariately to boost extraction efficiency. Under the optimum conditions, the detection limits calculated for the analytes were in the range of 0.20-8.0 ng/mL, and repeatability for six replicate measurements as indicated by percent relative standard deviation values were below 10%. Matrix matching calibration strategy was used to enhance quantification accuracy for the analytes. The percent recovery results calculated for the eleven analytes ranged between 86 and 117%.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10661-021-09708-5DOI Listing

Publication Analysis

Top Keywords

eleven nervous
8
pharmaceutical ingredients
8
liquid-phase microextraction
8
matrix matching
8
matching calibration
8
calibration strategy
8
switchable solvent
8
trace level
4
level determination
4
determination eleven
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!