Objective: Glenoid bone loss is estimated using a best-fit circle method and requires software tools that may not be available. Our hypothesis is that a vertical reference line drawn parallel to the long axis of the glenoid and passing through the inflection point of the coracoid and glenoid will represent a demarcation line of approximately 20% of the glenoid. Our aim is to establish a more efficient method to estimate a surgical threshold for glenoid insufficiency.

Methods: Fifty patients with normal glenoid anatomy were randomly chosen from an orthopedic surgeon's database. Two orthopedic surgeons utilized T1-weighted sagittal MRIs and the coracoglenoid line technique to determine the percentage of bony glenoid anterior to vertical line. Two musculoskeletal radiologists measured the same 50 glenoids using the circle technique. Differences were determined using dependent t test. Reliability was compared using interclass correlation coefficient and Kappa. Validity was compared using Pearson correlation coefficient.

Results: Mean surface area of the glenoid anterior to the vertical line was on average 21.69% ± 3.12%. Surface area of the glenoid using the circle method was on average 20.86% ± 2.29%. Inter-rater reliability of the circle method was 0.553 (fair). Inter-rater reliability of the vertical line technique was 0.83 (excellent). There was a linear relationship between circle and vertical line measurements, r = 0.704 (moderate to high).

Conclusion: The coracoglenoid line appears to represent a line of demarcation of approximately 21% of glenoid bone anterior to the coracoglenoid line. Our technique was found to be reliable, valid, and accurate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00256-021-03981-8DOI Listing

Publication Analysis

Top Keywords

glenoid bone
12
circle method
12
glenoid
11
anterior coracoglenoid
8
bone loss
8
represent demarcation
8
coracoglenoid technique
8
glenoid anterior
8
anterior vertical
8
surface area
8

Similar Publications

Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.

View Article and Find Full Text PDF

Eccentric Reaming is Superior to Augmented Components in B2 Glenoids: a Biomechanical study.

J Shoulder Elbow Surg

January 2025

Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada. Electronic address:

Introduction: Primary glenohumeral arthritis is typically associated with glenoid retroversion and posterior bone loss. Glenoid component fixation remains a weak link in the survivorship of anatomical total shoulder arthroplasty, particularly in the B2 glenoid. The aim of this study was to compare biomechanical properties of two glenoid preparation techniques in a B2 glenoid bone loss model.

View Article and Find Full Text PDF

Arthroscopic Bankart repair (ABR) is associated with an increased failure rate over time. The Recenter implant, a metal block, is designed to reinforce capsulolabral repair. The aim of this study was to evaluate whether the addition of the Recenter implant to ABR reduces the rate of recurrence in patients with glenohumeral anterior instability.

View Article and Find Full Text PDF

Objective: This study evaluated the effects of bony increased offset (BIO) and metallic augments (MAs) on primary reverse shoulder arthroplasty (RSA) baseplate stability in cadaveric specimens with variable bone densities.

Methods: Thirty cadaveric specimens were analyzed in an imaging and biomechanical investigation. Computed tomography (CT) scans allowed for preoperative RSA planning and bone density analysis.

View Article and Find Full Text PDF

Objectives: Anterior shoulder instability with minimal glenoid bone loss has several options for Bankart repair. We aimed to evaluate the results of a modified technique using two anchors with double and single loaded suture (three stitches in total) in arthroscopic Bankart surgery.

Methods: Thirty-eight patients underwent arthroscopic Bankart surgery and were assessed after an average 40 months follow-up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!