Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study uses a general formulation of integrated visual grading regression (IVGR) and applies it to cone beam computed tomography (CBCT) scan data related to anatomical landmarks for dental implantology. The aim was to assess and predict a minimum acceptable dose for diagnostic imaging and reporting. A skull phantom was imaged with a CBCT unit at various diagnostic exposures. Key anatomical landmarks within the images were independently reviewed by three trained observers. Each provided an overall image quality score. Statistical analysis was carried out to examine the acceptability of the images taken, using an IVGR analysis that was formulized as a three-stage protocol including defining an integrated score, development of an ordinal regression, and investigation of the possibility for dose reduction through estimated parameters. For a unit increase in the logarithm of radiation dose, the odds ratio that the integrated score for an image assessed by observers being rated in a higher category was 3.940 (95% confidence interval: 1.016-15.280). When assessed by the observers, the minimum dose required to achieve a 75% probability for an image to be classified as at least acceptable was 1346.91 mGy·cm dose area product (DAP), a 31% reduction compared to the 1962 mGy·cm DAP default dosage of the CBCT unit. The kappa values of the intra and inter-observer reliability indicated moderate agreements, while a discrepancy among observers was also identified because each, as expected, perceived visibility differently. The results of this work demonstrate the IVGR's predictive value of dose saving in the effort to reduce dose to patients while maintaining reportable diagnostic image quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00411-021-00959-x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!