A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High density avalanche chamber (HIDAC) positron camera. | LitMetric

A prototype positron camera has been constructed consisting of two high density avalanche chamber (HIDAC) detectors operated in coincidence with a resolving time (2 tau) of 40 nsec. The detectors are multiwire chambers, with specially constructed lead converters added to improve the photon detection efficiency at 511 keV. The current HIDAC detectors have a singles efficiency of approximately 12%, a sensitive area of 31 X 31 cm and an intrinsic spatial resolution of less than 2 mm full width at half maximum (FWHM). During data acquisition, the detectors are rotated around the patient in order to collect a complete angular data set. A three-dimensional image of the positron distribution is reconstructed from a single scan by weighted backprojection of the data into a matrix of either 64 X 64 X 64 or 128 X 128 X 16 voxels. The camera point response function is deconvolved by frequency-space filtering. Corrections are made during backprojection both for photon attenuation and for spatial variations in point source sensitivity. The reconstructed image is further corrected for contributions from accidental and scattered coincidences and displayed as a sequence of two-dimensional transverse, sagittal, or coronal sections. In addition, three-dimensional display is available using shaded graphics techniques. The prototype camera is currently undergoing clinical evaluation.

Download full-text PDF

Source

Publication Analysis

Top Keywords

high density
8
density avalanche
8
avalanche chamber
8
chamber hidac
8
positron camera
8
hidac detectors
8
hidac positron
4
camera
4
camera prototype
4
prototype positron
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!