Purpose: To summarize the graft loading, transporting and delivery devices used for endothelial keratoplasty (EK).

Methods: A literature search of electronic databases was performed.

Results: New techniques and devices have been introduced and implemented to prepare, load, transport and transplant the grafts for EK. The advantages are not only limited to the surgical theatre but also widely spread across the eye banking field. Investigation of advanced materials and designs have been rapidly growing with continuous evolution in the field of eye banking and corneal transplantation. Innovative techniques and modern devices have been evaluated to reduce the endothelial cell loss and increase the precision of the transplant in order to benefit both surgeons and the patients.

Conclusions: It is extremely important to reduce any potential wastage and optimize the use of every available donor cornea due to the limited availability of healthy cadaveric donor corneas required for transplants. As a result, the use of pre-cut and pre-loaded grafts supplied by the eye banks in calibrated devices have been gaining momentum. Innovation in the field of bioengineering for the development of new devices that facilitate excellent clinical outcomes along with reduction in learning curve has shown promising results.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713683.2021.2016852DOI Listing

Publication Analysis

Top Keywords

endothelial keratoplasty
8
eye banking
8
devices
6
delivering endothelial
4
keratoplasty grafts
4
grafts modern
4
modern day
4
day transplant
4
transplant devices
4
devices purpose
4

Similar Publications

Purpose: Descemet membrane endothelial keratoplasty (DMEK) has emerged as a novel approach in corneal transplantation over the past two decades. This study aims to identify predisposing risk factors for post-DMEK ocular hypertension (OHT) and develop a preoperative predictive model for post-DMEK OHT.

Methods: Patients who underwent DMEK at Gangnam Severance Hospital between 2017 and 2024 were included in the study.

View Article and Find Full Text PDF

Intracellular dark endothelial spots detected using specular microscopy are associated with graft failure after Descemet's membrane endothelial keratoplasty.

Graefes Arch Clin Exp Ophthalmol

January 2025

Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan.

Purpose: To investigate the correlation between intracellular dark endothelial spots (IDESs) detected by specular microscopy and the incidence of graft failure after Descemet's membrane endothelial keratoplasty (DMEK).

Methods: We reviewed 100 consecutive DMEK patients performed by a single surgeon at two centres between January 2015 and July 2022. Central corneal thickness was evaluated using anterior segment optical coherence tomography (SS-1000; Tomey, Aichi, Japan), and endothelial cell density was measured using specular microscopy.

View Article and Find Full Text PDF

: The aim of this study was to evaluate the effect of a surgical technique for managing post-penetrating keratoplasty (PK) ectasia complicated by late endothelial failure (LEF). : A single-center pilot case series was conducted regarding consecutive patients affected by post-PK ectasia with late graft failure. Using a microkeratome, a single donor cornea was dissected to prepare a two-piece graft, comprising a larger anterior lamella made up of anterior stroma and a smaller posterior lamella made up of posterior stroma, Descemet's membrane, and endothelium.

View Article and Find Full Text PDF

The World Health Organization estimates that approximately 285 million people suffer from visual impairments, around 5% of which are caused by corneal pathologies. Currently, the most common clinical treatment consists of a corneal transplant (keratoplasty) from a human donor. However, worldwide demand for donor corneas amply exceeds the available supply.

View Article and Find Full Text PDF

Background: The study aimed to review the etiology of corneal blindness and investigate the relative risk of corneal graft rejection (CGR) in the southern Liaoning region.

Methods: The clinical records of 359 patients (394 eyes) who underwent corneal transplantation at the Department of Keratoconus of the Third People's Hospital of Dalian from January 2019 to December 2023 were retrospectively analyzed. The data included patients' age, gender, occupation, diagnosis, surgical procedure, postoperative immune rejection, and neovascularization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!