Unstable Angina Induced by Fracture of a Recently Implanted Drug-Eluting Stent.

J Invasive Cardiol

First Department of Cardiology, 'Hippokration' General Hospital, National and Kapodistrian University of Athens, School of Medicine, Vasilissis Sofias Av. 114, 115 27, Athens, Greece.

Published: January 2022

Stent fracture is a rather infrequent complication associated with in-stent restenosis, thrombosis, aneurysm formation, and ischemic events. Several stent-related parameters, such as the use of longer or multiple stents, stent overlapping, and balloon/stent overexpansion are potential predictors of stent fracture. Stents deployed in right coronary artery lesions with exaggerated motion, tortuosity, or severe calcification are also generally considered to be at higher risk for fracture. This case demonstrates that intravascular ultrasound imaging is extremely useful to confirm the diagnosis and identify the possible mechanism of the stent fracture, as well as to assess the final result after subsequent angioplasty.

Download full-text PDF

Source
http://dx.doi.org/10.25270/jic/21.00259DOI Listing

Publication Analysis

Top Keywords

stent fracture
12
fracture
5
stent
5
unstable angina
4
angina induced
4
induced fracture
4
fracture implanted
4
implanted drug-eluting
4
drug-eluting stent
4
stent stent
4

Similar Publications

Percutaneous coronary intervention of a severely calcified coronary artery stenosis is associated with stent underexpansion and adverse outcomes. Intravascular lithotripsy (IVL) is a novel technology for fracturing calcified plaque in the coronary artery. We describe the first case of a severely calcified, undilatable coronary artery lesion.

View Article and Find Full Text PDF

We report a rare case of a missed intracavernous internal carotid artery dissecting aneurysm occurring as a complication of the base of skull fracture with severe brain injury causing acute cavernous sinus syndrome with permanent vision loss. A 31-year-old Myanmar lady had an alleged motor vehicle accident and suffered severe traumatic brain injury with multiple intracranial bleeds, multiple facial bone and base of skull fractures, and limb fractures. At one week post-trauma, she had severe right eye proptosis with vision loss, ophthalmoplegia, chemosis, and high intraocular pressure.

View Article and Find Full Text PDF
Article Synopsis
  • Heavily calcified coronary artery disease complicates percutaneous coronary intervention (PCI), requiring advanced techniques like cutting balloons (CB), which need standardization for better effectiveness.
  • The study presents the RODIN-CUT technique, which involves sequential CB inflations guided by intravascular ultrasound (IVUS) to improve plaque modification and stent expansion in difficult cases.
  • Results indicate that RODIN-CUT achieved high procedural success rates and minimal complications, suggesting it could be a simple and cost-effective method for treating calcified lesions, though larger studies are needed to confirm its validity.
View Article and Find Full Text PDF

The popliteal artery segment is particularly challenging for endovascular treatment. Stents used for treating popliteal artery lesions are usually associated with an increased risk of stent fracture and re-occlusion. The Supera stent is designed to withstand mechanical stress, with a low risk of fracture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!