Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Owing to the inadequate response to and limitations of the approved medications for androgenetic alopecia, novel therapies are warranted to enhance outcomes. The objective of this paper is to ascertain the effectiveness of fractional carbon dioxide laser followed by platelet-rich plasma application on hair regrowth and to compare the two laser settings. Seven participants were enrolled in this half-head pilot study based on different laser pulse energy and density values (12 mJ, 800 spots/cm and 22 mJ, 400 spots/cm). Ten treatment sessions were performed every 2 weeks with 12-week follow-up. The evaluation methods were based on hair density from standardized phototrichograms, global photographic assessment, and patient satisfaction. Significantly increased total and terminal hair densities were observed during treatment in both groups as compared with baselines. The mean total hair density has weekly increased significantly with high pulse energy (1.42 hair/cm) as compared to low pulse energy (1.04 hair/cm) throughout the study period (p = 0.023; 4.89 hair/cm). Global photographs and patient satisfaction scores demonstrated improvement, but only the latter showed statistical significance (p = 0.029). The average pain intensity scores were not different between the groups (p = 0.760) all over the procedure. The adverse events were minor and well tolerated. This synergistic treatment remarkably leads to hair restoration and high patient satisfaction. The parameters of 22-mJ beam energy with 400 spots/cm density are appropriate and superior to 12-mJ beam energy with 800 spots/cm. Albeit higher energy, no more pain is indicated in the high pulse energy group. Trial registration number (TRN): TCTR20180619004, Thai Clinical Trials Registry (TCTR) since 2018-05-15 13:39:48.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10103-021-03496-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!