Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The aim of the present study was to evaluate the sealing performance, expressed as microleakage (ML), of two root-end filling materials when used at different retro-preparation lengths.
Methods: Fifty single-rooted human teeth were collected for the study. The teeth were cut at the cement-enamel junction and endodontic treatment was performed. Each root was cut at 3 mm from the apex and then stored in wet condition. The teeth were divided into three groups according to the retro-preparation length: control group (no retro-preparation); group 1 (retro-preparation of 3 mm); group 2 (retro-preparation of 9 mm). The teeth were equally allocated to either Biodentine or Super EBA treatment group. The teeth were immersed in 3% methylene blue dye solution for 24 h. The samples were split longitudinally and the depth of dye penetration was examined through light microscopy.
Results: No significant statistical differences were found at different retro-preparation lengths (P > 0.05). Differences were found between materials (P > 0.05).
Conclusion: Biodentine showed significantly lower ML when compared to Super-EBA and no statistical significative differences were observed when samples were retro-prepared at 3 mm or 9 mm.