Objective: To evaluate the accuracy and reliability of a simple, single-camera smartphone-based method, named the Reflex Tracker (RT) system, for measuring reflex threshold angles related to ankle clonus and quadriceps hyperreflexia.
Design: A prospective comparison study using a high-fidelity reference standard was constructed employing a 2 × 2 × 2 factorial design, with factors of rater (tester) type (student and experienced physical therapist), joint (ankle and knee), and repetition (2 per condition).
Setting: This multicenter study was conducted at 4 outpatient rehabilitation clinics.
Participants: A convenience sample of 14 individuals with a neurologic condition presented with 20 lower limbs that exhibited ankle clonus and/or quadriceps hyperreflexia and were included in the study. Also participating in the study were 8 student and 8 experienced physical therapist raters (testers) (N=16).
Interventions: Not applicable.
Main Outcome Measures: The plantar flexor reflex threshold angle (PFRTA) related to ankle clonus and the quadriceps reflex threshold angle (QRTA) related to quadriceps hyperreflexia were quantified.
Results: PFRTA and QRTA results were compared between the smartphone RT method and synchronous 3-dimensional inertial measurement unit (IMU) sensor motion capture. Mean difference (bias) was minimal between RT and IMU measurements for PFRTA (bias≤0.2°) and QRTA (bias≤1.2°). Intrarater reliability for PFRTA ranged from 0.85-0.90 using RT and from 0.85-0.87 using IMU; QRTA ranged from 0.97-0.98 using RT and from 0.96-0.99 using IMU. Intersensor reliability for PFRTA and QRTA was 0.97 and 0.99, respectively. Minimum detectable change for PFRTA ranged from 7.1°- 8.7° and for QRTA ranged from 6.1°-8.3°.
Conclusions: RT performed comparable to IMU for accurate and reliable measurement of PFRTA and QRTA to quantify ankle clonus and quadriceps hyperreflexia in clinical settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8683842 | PMC |
http://dx.doi.org/10.1016/j.arrct.2021.100153 | DOI Listing |
Sci Transl Med
January 2025
Modular Implantable Neuroprostheses (MINE) Laboratory, Università Vita-Salute San Raffaele & Scuola Superiore Sant'Anna, 20132 Milan, Italy.
Spinal cord injury (SCI) causes severe motor and sensory deficits, and there are currently no approved treatments for recovery. Nearly 70% of patients with SCI experience pathological muscle cocontraction and spasticity, accompanied by clinical signs such as patellar hyperreflexia and ankle clonus. The integration of epidural electrical stimulation (EES) of the spinal cord with rehabilitation has substantial potential to improve recovery of motor functions; however, abnormal muscle cocontraction and spasticity may limit the benefit of these interventions and hinder the effectiveness of EES in promoting functional movements.
View Article and Find Full Text PDFNeuromodulation
January 2025
Department of Neurology, Graduate School of Medicine, Chiba University, Chiba, Japan.
Objectives: Intrathecal baclofen (ITB) therapy is well documented as an effective treatment option for severe spasticity. Before ITB implantation, trials are conducted to evaluate efficacy, safety, and candidate suitability. While many centers conduct ITB trials, appropriate physical assessment has not been fully established.
View Article and Find Full Text PDFNeurohospitalist
August 2024
Medicine Department, Federal University of Santa Maria, Santa Maria, Brazil.
Foot drop is a condition characterized by impairment of the ability to dorsiflex the foot at the ankle joint. We aim to review the literature and report a case of isolated unilateral foot drop of central causes. A 59-year-old male previously healthy presenting with a right foot drop was admitted.
View Article and Find Full Text PDFUlus Travma Acil Cerrahi Derg
November 2024
Department of Orthopedics, Odak Hospital, Denizli-Türkiye.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!