A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly Sensitive Electrochemical Aptasensor for Detection of Glypican-3 Using Hemin-Reduced Graphene Oxide-Platinum Nanoparticles Coupled with Conductive Reduced Graphene Oxide-Gold Nanoparticles. | LitMetric

An electrochemical aptasensor for quantitatively detecting glypican-3 (GPC3) was constructed by combining hemin-reduced graphene oxide-platinum (H-rGO-Pt) nanoparticles (NPs) with reduced graphene oxide-gold (rGO-Au) nanoparticles (NPs). Herein, the rGO-Au NPs deposited onto screen-printed electrodes resulted in signal amplification due to their large surface areas. Meanwhile, highly conductive H-rGO-Pt NPs acted as a sensing medium that improved electrical conductivity and as an indicator for monitoring peak current for determination. A GPC3 aptamer (GPC3apt) with a low equilibrium dissociation constant was used as a bio-recognition molecule. GPC3apt specifically captured GPC3 proteins and formed aptamer-GPC3 complexes, which impeded electron transfer and thus hampered the redox signal of hemin in H-rGO-Pt NPs. This developed electrochemical aptasensor showed a linear response to GPC3 (from 0.001 g/mL to 10 g/mL) and had a detection limit of 0.001 g/mL. This work provides a low-cost and highly sensitive detection with and good recovery for GPC3 and holds great promise for the clinical diagnosis of hepatocellular carcinoma.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jbn.2021.3215DOI Listing

Publication Analysis

Top Keywords

electrochemical aptasensor
12
highly sensitive
8
hemin-reduced graphene
8
graphene oxide-platinum
8
reduced graphene
8
graphene oxide-gold
8
nanoparticles nps
8
h-rgo-pt nps
8
0001 g/ml
8
gpc3
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!