A double crystal von Hamos spectrometer for traceable x-ray emission spectroscopy.

Rev Sci Instrum

Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin, Germany.

Published: December 2021

A novel double full-cylinder crystal x-ray spectrometer for x-ray emission spectroscopy (XES) has been realized based on a modified von Hamos geometry. The spectrometer is characterized by its compact dimensions, its versatility with respect to the number of crystals used in series in the detection path, and the option to perform calibrated XES measurements. The full-cylinder crystals used are based on highly annealed pyrolytic graphite with a thickness of 40 μm, which was bent to a radius of curvature of 50 mm. The flexible design of the spectrometer allows for an easy change-within the same setup-between measurements with one crystal for maximized efficiency or two crystals for increased spectral resolving power. The spectrometer realized can be used at different end-stations of synchrotron radiation beamlines or can be laboratory-based. The main application focus of the spectrometer is the determination of x-ray fundamental atomic parameters in the photon energy range from 2.4 to 18 keV. The evaluation of chemical speciation is also an area of application, as demonstrated in the example of battery electrodes using resonant inelastic x-ray scattering.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0061183DOI Listing

Publication Analysis

Top Keywords

von hamos
8
x-ray emission
8
emission spectroscopy
8
spectrometer
6
x-ray
5
double crystal
4
crystal von
4
hamos spectrometer
4
spectrometer traceable
4
traceable x-ray
4

Similar Publications

Reduced risk of hip fracture in women with endometrial cancer.

Int J Epidemiol

August 1992

Department of Obstetrics and Gynecology, University Hospital, Uppsala, Sweden.

The effect of excessive endogenous oestrogens on the risk of hip fracture was investigated in a population-based cohort of 2111 women with endometrial carcinoma who were followed up from age 50 years regarding the occurrence of a first hip fracture. Overall, 77 cases of hip fracture were observed, as against 120.8 expected, which meant a significantly reduced relative risk, standardized incidence ratio (SIR) = 0.

View Article and Find Full Text PDF

A new technique for radiotherapy in ovarian carcinoma is presented. The aim was to deliver a homogeneous radiation dose to the entire abdominal cavity. The whole abdomen, except for 20% of the upper compartment, received a homogeneous dose of 40 Gy, while 2/3 of the kidneys and the posterior part of the liver received a dose ranging from 40 to 20 Gy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!