Objective: To explore a new artificial intelligence (AI)-aided method to assist the clinical diagnosis of tibial plateau fractures (TPFs) and further measure its validity and feasibility.
Methods: A total of 542 X-rays of TPFs were collected as a reference database. An AI algorithm (RetinaNet) was trained to analyze and detect TPF on the X-rays. The ability of the AI algorithm was determined by indexes such as detection accuracy and time taken for analysis. The algorithm performance was also compared with orthopedic physicians.
Results: The AI algorithm showed a detection accuracy of 0.91 for the identification of TPF, which was similar to the performance of orthopedic physicians (0.92±0.03). The average time spent for analysis of the AI was 0.56 s, which was 16 times faster than human performance (8.44±3.26 s).
Conclusion: The AI algorithm is a valid and efficient method for the clinical diagnosis of TPF. It can be a useful assistant for orthopedic physicians, which largely promotes clinical workflow and further guarantees the health and security of patients.