The continuous quest for chromatographic supports offering kinetic performance properties superior to that of the packed bed of spheres has pushed the field to consider alternative formats such as for example monolithic and pillar array columns. This quest seems bound to culminate in the use of 3D printing technology, as this intrinsically offers the possibility to produce supports with a perfect uniformity and with a size and shape that is fully optimized for the chromatographic separation process. However, to be competitive with the current state-of-the-art, structures with sub-micron feature sizes are required. The present contribution therefore investigates the use of the 3D printing technology with the highest possible resolution available today, i.e., two-photon polymerization (2PP). It is shown that 2PP printing is capable of achieving the required ≤ 1 µm printing resolution. Depending on the laser scan speed, the lower limit through-pore size for a tetrahedral skeleton monolith with a theoretical 80% external porosity was found to be at 800 nm, when printing at a scan speed of 50 mm/s with a laser power of 10%. For a scan speed of 10 mm/s, the minimal through-pore size dropped to 500 nm. However, this very high resolution comes at the cost of excessively long printing times. The total printing time for a column volume equivalent to that of a typical nano-LC column (75 µm i.d. cylindrical tube with length L = 15 cm) has been determined to correspond to 330 and 470 h for the 50 mm/s and the 10 mm/s scan speed respectively. Other issues remaining to be solved are the need to clad the printed skeleton with a suitable mesoporous layer for chromatographic retention and the need to add a top-wall to the printed channels after the removal of the non-polymerized resin. It is therefore concluded that 2PP printing is not ready yet to replace the existing column fabrication methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2021.462763 | DOI Listing |
A compact and easy-to-use high-bandwidth autobalanced detector for microscopy is presented, being able to remove up to 67 dB of correlated noise, thus, allowing for shot-noise limited image acquisition even in the presence of high laser excess noise. Detecting a 20 MHz modulation frequency at half the repetition rate of the driving pulsed laser, the autobalanced detector is able to exploit an extra +3 dB increase in signal-to-noise ratio due to the coherent addition of modulation sidebands in stimulated Raman scattering. Pixel-by-pixel noise canceling and correction of sample transmission losses are possible for pixel scan rates of more than 1.
View Article and Find Full Text PDFNMR Biomed
March 2025
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single-sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave-CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
Department of Medical Imaging, Pingyin people's Hospital, Jinan 250400, China.
Magnetic Resonance Imaging is a cornerstone of medical diagnostics, providing high-quality soft tissue contrast through non-invasive methods. However, MRI technology faces critical limitations in imaging speed and resolution. Prolonged scan times not only increase patient discomfort but also contribute to motion artifacts, further compromising image quality.
View Article and Find Full Text PDFTomography
January 2025
Medical Physics Unit, IEO, European Institute of Oncology IRCCS, 20141 Milan, Italy.
Background: Computed tomography scans are widely used in everyday medical practice due to speed, image reliability, and detectability of a wide range of pathologies. Each scan exposes the patient to a radiation dose, and performing a fast estimation of the effective dose (E) is an important step for radiological safety. The aim of this work is to estimate E from patient and CT acquisition parameters in the absence of a dose-tracking software exploiting machine learning.
View Article and Find Full Text PDFPhotoacoustics
February 2025
School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China.
Photoacoustic tomography (PAT) enables non-invasive cross-sectional imaging of biological tissues, but it fails to map the spatial variation of speed-of-sound (SOS) within tissues. While SOS is intimately linked to density and elastic modulus of tissues, the imaging of SOS distribution serves as a complementary imaging modality to PAT. Moreover, an accurate SOS map can be leveraged to correct for PAT image degradation arising from acoustic heterogeneities.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!