Background: Automated magnetic resonance imaging (MRI) volumetry is a promising tool to evaluate regional brain volumes in dementia and especially Alzheimer's disease (AD).

Purpose: To compare automated methods and the gold standard manual segmentation in measuring regional brain volumes on MRI across healthy controls, patients with mild cognitive impairment, and patients with dementia due to AD.

Study Type: Systematic review and meta-analysis.

Data Sources: MEDLINE, Embase, and PsycINFO were searched through October 2021.

Field Strength: 1.0 T, 1.5 T, or 3.0 T.

Assessment: Two review authors independently identified studies for inclusion and extracted data. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2).

Statistical Tests: Standardized mean differences (SMD; Hedges' g) were pooled using random-effects meta-analysis with robust variance estimation. Subgroup analyses were undertaken to explore potential sources of heterogeneity. Sensitivity analyses were conducted to examine the impact of the within-study correlation between effect estimates on the meta-analysis results.

Results: Seventeen studies provided sufficient data to evaluate the hippocampus, lateral ventricles, and parahippocampal gyrus. The pooled SMD for the hippocampus, lateral ventricles, and parahippocampal gyrus were 0.22 (95% CI -0.50 to 0.93), 0.12 (95% CI -0.13 to 0.37), and -0.48 (95% CI -1.37 to 0.41), respectively. For the hippocampal data, subgroup analyses suggested that the pooled SMD was invariant across clinical diagnosis and field strength. Subgroup analyses could not be conducted on the lateral ventricles data and the parahippocampal gyrus data due to insufficient data. The results were robust to the selected within-study correlation value.

Data Conclusion: While automated methods are generally comparable to manual segmentation for measuring hippocampal, lateral ventricle, and parahippocampal gyrus volumes, wide 95% CIs and large heterogeneity suggest that there is substantial uncontrolled variance. Thus, automated methods may be used to measure these regions in patients with AD but should be used with caution.

Evidence Level: 3 TECHNICAL EFFICACY: Stage 3.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.28037DOI Listing

Publication Analysis

Top Keywords

parahippocampal gyrus
16
automated methods
12
subgroup analyses
12
lateral ventricles
12
mri volumetry
8
alzheimer's disease
8
systematic review
8
regional brain
8
brain volumes
8
manual segmentation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!