With the continued development and rapid growth of wearable technologies, PPG has become increasingly common in everyday consumer devices such as smartphones and watches. There is, however, minimal knowledge on the effect of the contact pressure exerted by the sensor device on the PPG signal and how it might affect its morphology and the parameters being calculated. This study explores a controlled in vitro study to investigate the effect of continually applied contact pressure on PPG signals (signal-to-noise ratio (SNR) and 17 morphological PPG features) from an artificial tissue-vessel phantom across a range of simulated blood pressure values. This experiment confirmed that for reflectance PPG signal measurements for a given anatomical model, there exists an optimum sensor contact pressure (between 35.1 mmHg and 48.1 mmHg). Statistical analysis shows that temporal morphological features are less affected by contact pressure, lending credit to the hypothesis that for some physiological parameters, such as heart rate and respiration rate, the contact pressure of the sensor is of little significance, whereas the amplitude and geometric features can show significant change, and care must be taken when using morphological analysis for parameters such as SpO2 and assessing autonomic responses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8706036 | PMC |
http://dx.doi.org/10.3390/s21248421 | DOI Listing |
J Clin Orthop Trauma
February 2025
Utah Valley Orthopedics and Sports Medicine, 1157 N 300 W, Provo, UT, 84604, USA.
Purpose: To review outcomes of medial patellofemoral ligament reconstruction (MPFLR) using synthetic suture tape in biomechanical and clinical studies.
Methods: A comprehensive literature search was performed in three databases. Studies reporting biomechanical and/or clinical outcomes of MPFLR using synthetic suture tape were included.
Front Cell Neurosci
January 2025
Department of Anatomy, Faculty of Medicine, Masaryk University, Brno, Czechia.
Introduction: The choroid plexus is located in the cerebral ventricles. It consists of a stromal core and a single layer of cuboidal epithelial cells that forms the blood-cerebrospinal barrier. The main function of the choroid plexus is to produce cerebrospinal fluid.
View Article and Find Full Text PDFRSC Adv
January 2025
Packing and Packaging Materials Department, Institute of Chemical Industries Research, National Research Centre 33 El Behooth St., Dokki Giza Egypt +20 2 33371718.
Nanofiltration (NF) separation technology is a low-pressure filtration process, which is highly efficient and environmentally friendly. As a result, it has found wide application in water treatment. This work describes the preparation of flat sheet membranes the phase inversion method using blends of hyperbranched polyester amide (PEA) and polyether sulphone (PES) in definite ratios.
View Article and Find Full Text PDFPurpose: To assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.
Methods: In this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.
Cureus
January 2025
Department of Ophthalmology, Shimane University Faculty of Medicine, Izumo, JPN.
Persistent hypotony following Tanito microhook trabeculotomy (TMH) is rare but may occur due to the development of cyclodialysis clefts. We report a case of a Japanese man in his 40s who developed persistent hypotony and hypotony maculopathy after TMH in the left eye. Fourteen months after the surgery, the patient was referred to our institution due to prolonged hypotony that remained undiagnosed and untreated despite evaluations with gonioscopy and anterior segment optical coherence tomography (AS-OCT) at the referring clinic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!