The clinical value of ultrasonic cardiac output monitor in very-low birth-weight and extremely-low-birth-weight infants undergoing PDA ligation.

Early Hum Dev

The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510280, China; Department of Neonatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China. Electronic address:

Published: February 2022

Background: Cardiorespiratory instability occurs very often in very-low-birth-weight (VLBW) and extremely-low-birth-weight (ELBW) infants undergoing patent ductus arteriosus (PDA) ligation during the early postoperative period. This study aimed to investigate ultrasonic cardiac output monitor (USCOM) as a bedside tool by evaluating the hemodynamic changes in preterm infants following PDA ligation and assessing factors that may influence these changes.

Methods: This was a single-center prospective observational study at a third-level neonatal intensive care unit. A total of 33 infants, including 21 VLBW and 12 ELBW infants, were involved. Hemodynamic measurements were performed in these infants using a USCOM preoperatively as well as 0-1 h, 8-10 h, and 24 h postoperatively.

Results: The PDA ligation was associated with reductions of the left ventricular cardiac output (LVCO) (P < 0.001), cardiac index (P < 0.001), flow time corrected (FTC) (P < 0.001), Smith-Madigan inotropy index (SMII) (P < 0.001), oxygen delivery (DO) (P < 0.001), and oxygen delivery index (DOI) (P < 0.001) and an increase of the systemic vascular resistance index (SVRI) (P < 0.001) at 0-1 h, 8-10 h, and 24 h post-ligation compared with the respective preoperative values. Compared with the respective values at 0-1 h post-ligation, there was no significant difference in the CI, SMII, or FTC at 8-10 h and 24 h post-ligation. However, the SVRI decreased at 8-10 h and 24 h post-ligation. Moreover, the DOI increased at 8-10 h and 24 h post-ligation, and the LVCO and DO increased at 24 h post-ligation.

Conclusion: Our study confirmed that the hemodynamic changes measured by the USCOM were similar to those measured by echocardiography in previous reports. Thus, USCOM is a useful and convenient bedside tool for assessing hemodynamic changes to guide the use of fluids, inotropic agents, and vasopressors and help modify the post-ligation course, and they may be a surrogate for repeated echocardiography during the early post-ligation period in preterm infants or a preliminary screening method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.earlhumdev.2021.105522DOI Listing

Publication Analysis

Top Keywords

pda ligation
16
cardiac output
12
ultrasonic cardiac
8
output monitor
8
infants undergoing
8
elbw infants
8
infants
6
clinical ultrasonic
4
monitor very-low
4
very-low birth-weight
4

Similar Publications

Article Synopsis
  • A unique case study describes a preschooler with a right-sided BH and patent ductus arteriosus (PDA), requiring two different surgical approaches for treatment.
  • This case is the first documented instance of a pediatric right-sided BH involving the appendix alongside congenital heart disease, leading to the proposal of the term Bhende-Pathak hernia for this variant.
View Article and Find Full Text PDF

Experience of patent ductus arteriosus ligation during extracorporeal membrane oxygenation treatment in newborns with severe respiratory failure due to persistent pulmonary hypertension: a single-center retrospective study.

Ital J Pediatr

November 2024

Department of Cardiac Surgery, Fujian Children's Hospital (Fujian Branch of Shanghai Children's Medical Center), College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China.

Background: The aim of this study is to summarize our center's experience with patent ductus arteriosus (PDA) ligation during extracorporeal membrane oxygenation (ECMO) treatment in newborns with severe respiratory failure due to persistent pulmonary hypertension of the newborn (PPHN).

Methods: We retrospectively collected and analyzed clinical data from five newborns with severe respiratory failure due to PPHN who underwent PDA ligation during ECMO treatment at our hospital between January 2021 and August 2023.

Results: All five patients had large PDAs, measuring 10 mm, 6 mm, 6 mm, 7 mm, and 6 mm, respectively.

View Article and Find Full Text PDF

Introduction/objective: Transcatheter therapeutics have revolutionized treatment of patent ductus arteriosus (PDA). Greater understanding of corrective interventions across species can advance best practices, protocols, and outcomes while minimizing adverse events. The objective of this study was to describe characteristics and outcomes in children and dogs undergoing transcatheter PDA occlusion.

View Article and Find Full Text PDF

Background: Pulmonary Artery Thrombosis (PAIST) refers to a thrombus forming within the pulmonary arterial system, distinct from an embolus originating from elsewhere in the body (e.g., the deep veins of the lower extremities) and traveling to the lungs where it lodges and forms.

View Article and Find Full Text PDF

Introduction: Patent ductus arteriosus (PDA) is a commonly encountered morbidity that occurs inversely with gestational age. In response to the growing trend of avoiding PDA ligation and prophylactic interventions, our center adopted a conservative approach starting in September 2020. This approach involves more precise fluid restriction for hemodynamically significant (hs) PDA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!