Bone cement leakage is a common complication of percutaneous vertebroplasty and it could be life-threatening to some extent. The aim of this study was to develop a machine learning model for predicting the risk of cement leakage in patients with osteoporotic vertebral compression fractures undergoing percutaneous vertebroplasty. Furthermore, we developed an online calculator for clinical application. This was a retrospective study including 385 patients, who had osteoporotic vertebral compression fracture disease and underwent surgery at the Department of Spine Surgery, Liuzhou People's Hospital from June 2016 to June 2018. Combing the patient's clinical characteristics variables, we applied six machine learning (ML) algorithms to develop the predictive models, including logistic regression (LR), Gradient boosting machine (GBM), Extreme gradient boosting (XGB), Random Forest (RF), Decision Tree (DT) and Multilayer perceptron (MLP), which could predict the risk of bone cement leakage. We tested the results with ten-fold cross-validation, which calculated the Area Under Curve (AUC) of the six models and selected the model with the highest AUC as the excellent performing model to build the web calculator. The results showed that Injection volume of bone cement, Surgery time and Multiple vertebral fracture were all independent predictors of bone cement leakage by using multivariate logistic regression analysis in the 385 observation subjects. Furthermore, Heatmap revealed the relative proportions of the 15 clinical variables. In bone cement leakage prediction, the AUC of the six ML algorithms ranged from 0.633 to 0.898, while the RF model had an AUC of 0.898 and was used as the best performing ML Web calculator (https://share.streamlit.io/liuwencai0/pvp_leakage/main/pvp_leakage) was developed to estimate the risk of bone cement leakage that each patient undergoing vertebroplasty. It achieved a good prediction for the occurrence of bone cement leakage with our ML model. The Web calculator concluded based on RF model can help orthopedist to make more individual and rational clinical strategies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8702729PMC
http://dx.doi.org/10.3389/fpubh.2021.812023DOI Listing

Publication Analysis

Top Keywords

bone cement
32
cement leakage
32
machine learning
12
percutaneous vertebroplasty
12
web calculator
12
cement
9
bone
8
leakage
8
patients osteoporotic
8
osteoporotic vertebral
8

Similar Publications

This in vitro study aims to evaluate various surface treatments on the shear bond strength and failure mode of CAD/CAM PMMA teeth to the heat-polymerized acrylic denture base. The study sample consisted of 100 teeth that were divided equally into five groups: Group 1: denture artificial teeth (control), Group 2: PMMA teeth without surface treatment, Group 3: PMMA teeth with MMA etching, Group 4: PMMA teeth with sandblasting (aluminum oxide particles), and Group 5: PMMA teeth with perpendicular grooves. The shear bond strength test was performed using a universal testing machine and the failure mode was recorded.

View Article and Find Full Text PDF

Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.

Description: The procedure can be completed in a standard operating theater without the need for special instruments.

View Article and Find Full Text PDF

To exclusively evaluate, in vitro, the efficacy of five intracanal medicaments against Candida albicans and Enterococcus faecalis in infected single-rooted primary teeth. Forty-three teeth were selected, out of which 42 were simultaneously contaminated with C. albicans and E.

View Article and Find Full Text PDF

Objective: Transcutaneous osseointegration prosthetic systems (TOPS) offer a stable skeletal attachment for artificial limbs post-extremity amputation, serving as an alternative to socket attachment. Press-fit osseointegration implants (OI) utilized in TOPS consistently enhance quality of life and mobility for amputees, particularly those experiencing socket-related issues. Despite notable benefits, late complications such as infection and implant loosening pose challenges unique to TOPS due to their percutaneous nature.

View Article and Find Full Text PDF

: Vancomycin is commonly used in the treatment of periprosthetic joint infection (PJI), and trough concentrations are measured to ascertain that they are within the therapeutic range. It has not been investigated what proportion of vancomycin concentrations during treatment of PJI patients is accurately within this range, how many dose adjustments are commonly needed, and which patient factors predispose towards aberrations from the desired range. : In this single-center cohort study, we investigated vancomycin trough concentrations in 108 patients with surgically treated PJI who received IV administered vancomycin treatment post-operatively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!