Computational Analysis of Mapping Catheter Geometry and Contact Quality Effects on Rotor Detection in Atrial Fibrillation.

Front Physiol

Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy.

Published: December 2021

Atrial fibrillation (AF) is the most common cardiac arrhythmia and catheter mapping has been proved to be an effective approach for detecting AF drivers to be targeted by ablation. Among drivers, the so-called rotors have gained the most attention: their identification and spatial location could help to understand which patient-specific mechanisms are acting, and thus to guide the ablation execution. Since rotor detection by multi-electrode catheters may be influenced by several structural parameters including inter-electrode spacing, catheter coverage, and endocardium-catheter distance, in this study we proposed a tool for testing the ability of different catheter shapes to detect rotors in different conditions. An approach based on the solution of the monodomain equations coupled with a modified Courtemanche ionic atrial model, that considers an electrical remodeling, was applied to simulate spiral wave dynamics on a 2D model for 7.75 s. The developed framework allowed the acquisition of unipolar signals at 2 KHz. Two high-density multipolar catheters were simulated (Advisor™ HD Grid and PentaRay) and placed in a 2D region in which the simulated spiral wave persists longer. The configuration of the catheters was then modified by changing the number of electrodes, inter-electrodes distance, position, and atrial-wall distance for assessing how they would affect the rotor detection. In contact with the wall and at 1 mm distance from it, all the configurations detected the rotor correctly, irrespective of geometry, coverage, and inter-electrode distance. In the HDGrid-like geometry, the increase of the inter-electrode distance from 3 to 6 mm caused rotor detection failure at 2 mm distance from the LA wall. In the PentaRay-like configuration, regardless of inter-electrode distance, rotor detection failed at 3 mm endocardium-catheter distance. The asymmetry of this catheter resulted in rotation-dependent rotor detection. To conclude, the computational framework we developed is based on realistic catheter shapes designed with parameter configurations which resemble clinical settings. Results showed it is well suited to investigate how mapping catheter geometry and location affect AF driver detection, therefore it is a reliable tool to design and test new mapping catheters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696082PMC
http://dx.doi.org/10.3389/fphys.2021.732161DOI Listing

Publication Analysis

Top Keywords

rotor detection
24
inter-electrode distance
12
distance
9
mapping catheter
8
catheter geometry
8
atrial fibrillation
8
endocardium-catheter distance
8
catheter shapes
8
spiral wave
8
catheter
7

Similar Publications

High-voltage overhead power lines serve as the carrier of power transmission and are crucial to the stable operation of the power system. Therefore, it is particularly important to detect and remove foreign objects attached to transmission lines, as soon as possible. In this context, the widespread promotion and application of smart robots in the power industry can help address the increasingly complex challenges faced by the industry and ensure the efficient, economical, and safe operation of the power grid system.

View Article and Find Full Text PDF

Large amplitude motions (LAMs), most notably represented by proton tunneling, mark a significant departure from small amplitude vibrations where protons merely oscillate around their equilibrium positions. These substantial displacements require tunneling through potential energy barriers, leading to splittings in, e.g.

View Article and Find Full Text PDF

University of Ottawa constant and variable speed electric motor vibration and acoustic fault signature dataset.

Data Brief

April 2024

Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada.

Induction motors are used in industry as they are self-starting, reliable, and affordable. Applications for these motors include lathes, mills, pumps, power conveyor belts, and commercial electrical and hybrid vehicles. Induction motors have various types of failures, including rotor unbalance, rotor misalignment, stator winding faults, voltage unbalance, bowed rotor, broken rotor bars, and faulty bearings.

View Article and Find Full Text PDF

Supramolecular Rotor Assembly for the Design of a Hybrid Ferroelectric-Antiferromagnetic Multiferroic Semiconductor.

Angew Chem Int Ed Engl

December 2024

Chaotic Matter Science Research Center, Jiangxi Province Key Laboratory of Functional Crystalline Materials Chemistry, International Institute for Innovation, Jiangxi University of Science and Technology, Ganzhou, 341000, P.R. China.

Ferroelectric (FE)-antiferromagnetic (AFM) multiferroic materials have sparked growing interest due to their huge possibilities in energy-saving, photoelectric devices, nonvolatile storage, and switches. However, realizing FE-AFM properties in a hybrid molecular material is difficult because ferroelectric and magnetic orders are commonly mutually exclusive. Here, we report an FE-AFM multiferroic semiconductor [NH(18-crown-6)][Mn(SCN)] (NCMS) by supramolecular assembly approach via molecular rotor synthon [NH(18-crown-6)] and inorganic magnetic module [Mn(SCN)].

View Article and Find Full Text PDF

Designing artificial fluorescent proteins and biosensors by genetically encoding molecular rotor-based amino acids.

Nat Chem

December 2024

State Key Laboratory of Natural and Biomimetic Drugs, Chemical Biology Center, Department of Molecular and Cellular Pharmacology, School of Pharmaceutical Sciences, Peking University, Beijing, China.

Article Synopsis
  • Fluorescent proteins are vital in research, serving as tools for studying biological processes due to their ability to emit light when excited.
  • Inspired by natural fluorophores, researchers created fluorescent molecular rotor amino acids (FMR-AAs) that mimic the fluorescence properties of these proteins.
  • By integrating FMR-AAs into various proteins, scientists can create artificial fluorescent proteins and effective biosensors to monitor interactions and changes within proteins in live cells and lab settings.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!