Objective: To report on long-acting reversible contraception (LARC) experience and continuation rates in the Adolescent Medicine LARC Collaborative.
Study Design: LARC insertion data (682 implants and 681 intrauterine devices [IUDs]) were prospectively collected from January 1, 2017, through December 31, 2019, across 3 Adolescent Medicine practices. Follow-up data through December 31, 2020, were included to ensure at least 1 year of follow-up of this cohort. Continuation rates were calculated at 1, 2, and 3 years, overall and by Adolescent Medicine site, as were descriptive statistics for LARC procedural complications and patient experience.
Results: Implant and IUD insertion complications were uncommon and largely self-limited, with no IUD-related uterine perforations. Uterine bleeding was the most frequently reported concern at follow-up (35% implant, 25% IUD), and a common reason for early device removal (45% of implant removals, 32% of IUD removals). IUD malposition or expulsion occurred following 6% of all insertions. The pooled implant continuation rate at 1 year was 87% (range, 86%-91% across sites; P = .63), 66% at 2 years (range, 62%-84%; P = .01), and 42% at 3 years (range, 36%-60%; P = .004). The pooled IUD continuation rate at 1 year was 88% (range, 87%-90% across sites; P = .82), 77% at 2 years (range, 76%-78%; P = .94), and 60% at 3 years (range, 57%-62%; P = .88).
Conclusions: LARC is successfully provided in Adolescent Medicine clinical settings, with continuation rates analogous to those of well-resourced clinical trials. Uterine bleeding after LARC insertion is common, making counselling imperative. Future analyses will assess whether the medical management of LARC-related nuisance bleeding improves continuation rates in our Adolescent Medicine patient population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpeds.2021.11.077 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!