Background: Microfocused ultrasound with visualization (MFU-V; Ultherapy , Merz North America) is US Food and Drug Administration-cleared as a non-invasive procedure that lifts the soft tissue of the neck, submentum and brow, and improves lines and wrinkles on the upper chest. Several other energy-based devices are in use in countries outside the USA where they are marketed for indications similar to those of MFU-V, although published studies supporting these indications are limited and none of the other devices provides visualization or verification they reach the superficial musculoaponeurotic system.
Methods: Due to the evolving landscape of ultrasound technology as more devices enter the market, seven global thought leaders who are qualified experts on the use of various high-intensity focused ultrasound (HIFU)/MFU-V technologies convened to review data from an independent evaluation of the software, thermal characteristics, transducer acoustics and ultrasound therapy of MFU-V and three other ultrasound-based devices.
Results: The independent testing demonstrated the devices have key differences in several parameters that play a role in safety and effectiveness. Specifically, MFU-V has visualization capability but the other devices lack that feature. Other differences include the retention of patient history, consistent size and uniformity of thermal coagulation points (TCPs), precise localization of energy concentration at the focal point, and reliable thermal regulation during use. The expert panel established a consensus on the types of preventable complications associated with ultrasound-based energy devices and techniques for preventing and treating complications.
Conclusions: The independent test results of MFU-V/HIFU devices and the consensus panel conclusions provide strong support that real-time visualization and the capability to detect coupling, features found only in MFU-V, help prevent complications and enhance the safety and effectiveness of energy-based devices. The independent evaluation also revealed that MFU-V has several additional features that play key roles in safety and clinical effectiveness, including uniformity of TCPs, tight thermal regulation, large focal gain, and short beam length, that were not found collectively in any of the HIFU devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9305832 | PMC |
http://dx.doi.org/10.1111/jocd.14666 | DOI Listing |
Surg Innov
January 2025
Department of Otolaryngology - Head & Neck Surgery, Kirk Kerkorian School of Medicine at UNLV, Las Vegas, NV, USA.
Objective: The Thunderbeat (TB) is a new surgical device that combines ultrasonic and bipolar energy. The objective of this study is to examine how the combined ultrasonic and bipolar shears affect surgical outcomes when compared to other methods.
Data Sources And Review Methods: Using the PRISMA guidelines, the researchers used broad search terms in PubMed, Embase, and Web of Science, which produced a total of 2823 initial results, with years ranging from 1955 to June 2024.
Sci Rep
December 2024
Chitkara Centre for Research and Development, Chitkara University, Baddi, 174103, Himachal Pradesh, India.
This paper addresses the smart management and control of an independent hybrid system based on renewable energies. The suggested system comprises a photovoltaic system (PVS), a wind energy conversion system (WECS), a battery storage system (BSS), and electronic power devices that are controlled to enhance the efficiency of the generated energy. Regarding the load side, the system comprises AC loads, DC loads, and a water pump.
View Article and Find Full Text PDFInt J Surg
October 2024
Department of Surgery, Sapienza University of Rome, Rome, Italy.
Background: One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves' injury. The "clamp and tie" technique was first introduced in the 19th century.
View Article and Find Full Text PDFAesthetic Plast Surg
December 2024
Research and Innovation Hub, Innovation Aesthetics, London, WC2H 9JQ, UK.
Introduction: Aesthetic medicine has evolved towards minimally invasive procedures, with biostimulators like Poly-L-Lactic Acid (PLLA), Calcium Hydroxylapatite (CaHA), and Polycaprolactone (PCL) gaining attention for their role in collagen induction, improving skin texture, elasticity, and volume. Combining these agents with other treatments-such as botulinum toxin, dermal fillers, and energy-based devices (e.g.
View Article and Find Full Text PDFLasers Surg Med
December 2024
Center for Cancer Immunology and Cutaneous Biology Research Center, Department of Dermatology and Center for Cancer Research, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Objective: Physical treatment modalities, such as ablative fractional laser (AFL), electrocautery, and cryotherapy, are extensively used in the field of dermatology. This study aimed to characterize the short-term innate and adaptive immune responses induced by AFL compared with heat- and cold-based procedures.
Materials And Methods: Innate (CD11bLy6G neutrophils) and adaptive (CD8CD3 T cells) immune cell infiltration and histopathological changes were examined in murine skin on Days 1 and 7, following AFL, monopolar-electrocautery (RF), thermocautery, and cryotherapy.