Patients undergoing pelvic radiotherapy are often advised to omit fiber-rich foods from their diet to reduce the adverse effects of treatment. Scientific evidence supporting this recommendation is lacking, and recent studies on animals and humans have suggested that there is a beneficial effect of dietary fiber for the alleviation of symptoms. Randomized controlled studies on dietary fiber intake during pelvic radiotherapy of sufficient size and duration are needed. As preparation for such a large-scale study, we evaluated the feasibility, compliance, participation rate, and logistics and report our findings here in this preparatory study. In this preparatory study of a fiber intervention trial, Swedish gynecological cancer patients scheduled for radiotherapy were recruited between January 2019 and August 2020. During the intervention, the participants filled out questionnaires and used an application. They also consumed a fiber supplement at first in powder form, later in capsules. Blood- and fecal samples were collected. The study is registered in clinicaltrials.gov (https://clinicaltrials.gov/ct2/show/NCT04534075?cond=fidura&draw=2&rank=1). Among 136 approached patients, 57 started the study and the participation rate for primary outcomes was 63% (third blood sample) and 65% (third questionnaire). Barely half of the participants provided fecal samples. Providing concise and relevant information to the patients at the right time was crucial in getting them to participate and stay in the study. The most common reasons for declining participation or dropping out were the expected burden of radiotherapy or acute side effects. Tailoring the ambition level to each patient concerning the collection of data beyond the primary endpoints was an important strategy to keep the dropout rate at an acceptable level. Using capsules rather than psyllium in powder form made it much easier to document intake and to create a control group. During the course of the preparatory study, we improved the logistics and for the last 12 participants included, the participation rate was 100% for the earliest primary outcome. A variety of adjustments in this preparatory study resulted in an improved participation rate, which allowed us to set a final protocol and proceed with the main study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8688914PMC
http://dx.doi.org/10.3389/fnut.2021.756485DOI Listing

Publication Analysis

Top Keywords

preparatory study
20
participation rate
16
dietary fiber
12
pelvic radiotherapy
12
study
9
randomized controlled
8
fiber intake
8
powder form
8
fecal samples
8
study improved
8

Similar Publications

We present a comprehensive analysis of the optical attributes of graphene sheets with charge carriers residing on a curved substrate. In particular, we focus on the fascinating case of Beltrami geometry and provide an explicit parametrization for this curved two-dimensional surface. By employing the massless Dirac description that is characteristic of graphene, we investigate the impact of the curved geometry on the optical properties within the sample.

View Article and Find Full Text PDF

The present study quantified simultaneous determination of the active components included in Valzomix HCT tablets are hydrochlorothiazide (HCT), valsartan (VAL), and amlodipine (AML). Two chemometric methods-continuous wavelet transform (CWT) and ratio subtraction (RS)-along with a rapid and effective spectrophotometric approach-which does not require preparatory separation-were used to do the analysis. The CWT approach applied the zero-crossing method to analyze several wavelet families and selected the Daubechies 2, Symlet 2, and Biorthogonal 1.

View Article and Find Full Text PDF

Introduction: This study aimed to assess current practice in general x-ray rooms in three Irish hospitals. Evaluating the extent to which x-ray protocols are currently standardised can be considered as a preparatory step towards the larger goal of implementing optimisation in a diagnostic radiology department.

Methods: Data on various aspects of general x-ray room exposures was manually collected and analysed to highlight variations with exposure factors in use and workload distribution across each of the ten hospital x-ray rooms included in the study.

View Article and Find Full Text PDF

Pupil size is a well-established marker of cognitive effort, with greater efforts leading to larger pupils. This is particularly true for pupil size during task performance, whereas findings on anticipatory effort triggered by a cue stimulus are less consistent. For example, a recent report by Frömer et al.

View Article and Find Full Text PDF

Manipulating flexible and underactuated objects, such as a whip, remains a significant challenge in robotics. Remarkably, humans can skillfully manipulate such objects to achieve tasks, ranging from hitting distant targets to extinguishing a cigarette's in someone's mouth with the tip of a whip. This study explored this problem by constructing and modeling a 25-degree-of-freedom whip.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!