A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Numerical Analysis of Stapes Prosthesis Constraining in the Case of Otosclerosis. | LitMetric

Numerical Analysis of Stapes Prosthesis Constraining in the Case of Otosclerosis.

Materials (Basel)

Faculty of Mechanical Engineering and Design, Kaunas University of Technology, Studentų Str. 56, 51424 Kaunas, Lithuania.

Published: December 2021

In the case of otosclerosis, it has been noticed that even though there are a variety of different prostheses on the market, due to the anatomical characteristics, it is not always possible to restore excellent mobility to the ossicles and the prosthesis. On the one hand, this happens because the incus long process and the prosthesis create difficult angles. On the other hand, incus necrosis is among the most common causes of the loss of stability to the prosthesis and stapedectomy failure. The aim of this research is to suggest an improvement for stapes prosthesis stability and numerically evaluate the impact of the prosthesis constraining to its dynamical behavior. Numerical 3D models of a standard as well as a modified (adjustable angled) stapes prosthesis were created in order to achieve this aim. Consequently, the modal analysis has been performed to evaluate the mechanical behavior of the prosthesis, assuming that the piston (thick part) would be made of Teflon, and the thin part, fixated on the incus long process, would be made from titanium alloy. Finally, the numerical analysis has been conducted by changing the boundary conditions in respect of the prosthesis constraining, where the attached stapes prosthesis connects to the ossicular chain. Subsequently, there were two hypotheses raised for the prosthesis loop constraining. The first is that during the surgery, the prosthesis is perfectly crimped with certain looseness. The second is that the prosthesis is outgrown by the tissues over time and thus becomes over-constrained. Then, the analyzed standard stapes prosthesis does not fulfil its functions because of the over-constraining that develops over time. An improvement for the standard stapes prosthesis, i.e., a modified stapes prosthesis (adjustable angled), that has been proposed in this research allows avoidance of the negative effects of the over-constrained standard stapes prosthesis that appear over time. Moreover, the proposed modified prosthesis helps to regain hearing when the angle between the incus long process and prosthesis is unfavorable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8703647PMC
http://dx.doi.org/10.3390/ma14247747DOI Listing

Publication Analysis

Top Keywords

stapes prosthesis
32
prosthesis
19
prosthesis constraining
12
incus long
12
long process
12
standard stapes
12
numerical analysis
8
stapes
8
case otosclerosis
8
hand incus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!