AI Article Synopsis

  • Food allergies are caused by hypersensitivity to specific allergens, like egg proteins, making it crucial to test food products for their presence to avoid accidental ingestion.
  • Current testing methods, like ELISA, detect egg allergens but can produce false negatives due to food processing; mass spectrometry methods are less sensitive.
  • Researchers developed a new immunoaffinity LC-MS/MS technique that combines both antibody and mass spectrometry approaches, showing sensitivity similar to ELISA while being less affected by food processing.

Article Abstract

Food allergies are caused by severe hypersensitivity to specific food allergens such as the egg protein ovalbumin. It is therefore important to test food products for the presence of allergens to protect allergic people from accidental ingestion. For egg detection, ELISA is the only reasonable commercially available test format, although the recognition of target allergens can be affected by food processing, which may lead to false negative results. Current mass spectrometry-based detection methods may overcome this issue, but these approaches are often less sensitive. Here we combined the advantages of antibody-based and MS-based methods by developing an immunoaffinity LC-MS/MS technique to detect the common egg allergen Gal d 2. We investigated the principal functionality of this method with incurred cookie material containing whole egg powder. We found that the new method matched easily the sensitivity of egg specific ELISA tests. Further western blot experiments indicated that this strategy may be unaffected by food processing, providing an important alternative strategy for the detection and quantification of allergens in food.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700968PMC
http://dx.doi.org/10.3390/foods10122932DOI Listing

Publication Analysis

Top Keywords

immunoaffinity lc-ms/ms
8
allergens food
8
food processing
8
food
6
egg
5
improved sensitivity
4
sensitivity allergen
4
detection
4
allergen detection
4
detection immunoaffinity
4

Similar Publications

Antibody-drug conjugates (ADCs) are intricate compounds that pose significant challenges in bioanalytical characterization. Therefore, multiple bioanalytical methods are required to comprehensively elucidate their pharmacokinetic (PK) profiles. In this study, we investigated DS001, an ADC consisting of a humanized monoclonal antibody (hRS7), a cleavable chemical linker, and the microtubule inhibitor monomethyl auristatin E (MMAE), with a drug-to-antibody ratio (DAR) of 8.

View Article and Find Full Text PDF

Objectives: An analytical protocol based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS), which includes a peptide-based calibration strategy, was developed and validated for the determination of cardiac troponin I (cTnI) levels in clinical samples. Additionally, the developed method was compared with a protein-based calibration strategy, using cTnI serving as a model for low-abundant proteins. The aim is to evaluate new approaches for protein quantification in complex matrices, supporting the metrology community in implementing new methods and developing fit-for-purpose SI- traceable peptide or protein primary calibrators.

View Article and Find Full Text PDF

Background: The 11+Myco MS-PREP® Immunoaffinity Column (IAC) contains a gel suspension of monoclonal antibodies specific to the toxins of interest. Following sample extraction, the IAC is used for cleanup and concentration of mycotoxins prior to analysis by Liquid Chromatography with Tandem Mass Spectrometry (LC-MS/MS).

Objective: This study evaluated the IAC with LC-MS/MS method for Performance Tested Methods  SM certification for simultaneous determination and confirmation of Aflatoxins B1, B2, G1, G2, and M1; Deoxynivalenol, Fumonisins B1, B2, and B3; Ochratoxin A; T-2; HT-2; and Zearalenone from corn, wheat, cereal-based baby food (with and without dairy ingredients), paprika, chili powder and animal feed.

View Article and Find Full Text PDF

CKD is frequently diagnosed only after a significant progression. GFR is the most common indicator of kidney function but is limited in detecting early CKD cases and distinguishing glomerular, tubular, and global CKD. Aiming to provide a glomeruli specific biomarker assay, we developed a peptide immunoaffinity targeted mass spectrometry method for the quantitation of three podocyte specific proteins in human urine: nephrin, podocalyxin, and podocin.

View Article and Find Full Text PDF

Objectives: Automated immunoassays for 1,25-dihydroxyvitamin D (1,25(OH)D) have increased the use of serum measurements in clinical and research settings, but disagreement with LC-MS/MS methods remains an issue.

Methods: In this study, we examined this problem using samples obtained from healthy young adults, n=80, mean age 21.7 (18-32) years, and a large cohort of paediatric samples, n=422, mean age 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!