A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultra-Short Bone Conserving Cementless Femoral Stem. | LitMetric

Ultra-Short Bone Conserving Cementless Femoral Stem.

Hip Pelvis

The Joint Replacement Center, Seoul Metropolitan SeoNam Hospital, Seoul, Korea.

Published: December 2021

Excellent long-term results have been reported with conventional length cementless femoral stems in total hip arthroplasty; however, proximal stress shielding and thigh pain are still a concern. Metaphyseal engaging bone conserving short stems provide theoretical benefits compared with conventional length cementless stems, including avoiding proximal-distal mismatch, decreasing proximal stress shielding, and limiting perioperative fractures. The purpose of the ultra-short bone conserving cementless stem was to reproduce natural load transfer with an ultra-short stem obtaining optimal stability using the morphology of the proximal femur. Loss of stability of the stem and failure of osseous ingrowth is a potential concern with the use of ultra-short proximal loading cementless femoral stems. Ultra-short, metaphyseal-fitting anatomic or non-anatomic cementless femoral stems provided stable fixation without relying on diaphyseal fixation in young and elderly patients, suggesting that metaphyseal-fitting alone is sufficient in young and elderly patients who have good bone quality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8654591PMC
http://dx.doi.org/10.5371/hp.2021.33.4.181DOI Listing

Publication Analysis

Top Keywords

cementless femoral
16
bone conserving
12
femoral stems
12
ultra-short bone
8
conserving cementless
8
conventional length
8
length cementless
8
proximal stress
8
stress shielding
8
young elderly
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!