Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Real-time and sensitive detection of pathogenic bacteria in food is in high demand to ensure food safety. In this study, a single-walled carbon nanotubes (SWCNTs)-based electrochemical impedance immunosensor for on-site detection of Listeria monocytogenes (L. monocytogenes) was developed. A gold-plated wire was functionalized using polyethylenimine (PEI), SWCNTs, streptavidin, biotinylated L. monocytogenes antibodies, and bovine serum albumin (BSA). A linear relationship (R = 0.982) between the electron transfer resistance measurements and concentrations of L. monocytogenes within the range of 10 -10 CFU/ml was observed. In addition, the sensor demonstrated high selectivity towards the target in the presence of other bacterial cells such as Salmonella Typhimurium and Escherichia coli O157:H7. To facilitate the demand for on-site detection, the sensor was integrated into a smartphone-controlled biosensor platform, consisting of a compact potentiostat device and a smartphone. The signals from the proposed platform were compared with a conventional potentiostat using the immunosensor interacted with L. monocytogenes (10 -10 CFU/ml). The signals obtained with both instruments showed high consistency. Recovery percentages of lettuce homogenate spiked with 10 , 10 , and 10 CFU/ml of L. monocytogenes obtained with the portable platform were 90.21, 90.44, and 93.69, respectively. The presented on-site applicable SWCNT-based immunosensor platform was shown to have a high potential to be used in field settings for food and agricultural applications. PRACTICAL APPLICATION: The developed immunosensor was developed for on-site detection of L. monocytogenes. The limit of detection of the sensor was 10 CFU/ml with a detection time of 10 min. In order to facilitate the requirements for effective on-site screening for food safety, the sensor was integrated into a smartphone-controlled platform, so that the bio-molecular interactions were converted into impedance signals and transmitted wirelessly to a smartphone by a hand-held EIS transducer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1750-3841.15996 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!