A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Patient Reported Quality of Life Outcomes After Definitive Radiation Therapy With Absorbable Spacer Hydrogel for Prostate Cancer. | LitMetric

Purpose: SpaceOAR is a device approved for conventional radiation in prostate cancer. We sought to observe prospectively how SpaceOAR Hydrogel effected quality of life and dosimetry to organs at risk at our institution.

Methods And Materials: We prospectively enrolled patients with low risk or favorable-intermediate risk localized prostate cancer. Baseline Expanded Prostate Cancer Index Composite (EPIC-26) scores along with baseline American Urology Association Symptom Index (AUA-SI) scores were collected. SpaceOAR was placed for all patients who then received stereotactic body radiation therapy, low dose rate brachytherapy, conventionally fractionated radiation therapy, or moderately hypofractionated radiation therapy. We evaluated postimplant dosimetry to critical structures, and prospectively collected follow-up EPIC-26 and AUA-SI scores. We performed a repeated measures analysis of variance to compare patient-specific responses and correlated survey data with dosimetric metrics by generating linear regression models.

Results: We enrolled 59 patients in this study with a median follow-up of 366 days (interquartile range, 507). At final follow-up, the "?>prostate-specific antigen had a significant decline compared with baseline ( < .0001). There were no grade 3 toxicities on treatment. There were no significant changes in the AUA-SI score ( = .69) at final follow-up compared with baseline, nor was there any change in EPIC-26 domain scores ( = .19) during the course of the study period. There were no significant associations between AUA scores and EPIC-26 scores and the dose to the rectum, bladder, or urethra with the exception being dose to the 2 mL rectum correlated with decline in EPIC-26 rectal score (β, -0.002;  = .006). Patient-reported declines in bowel domains were less than previously reported data.

Conclusions: Use of SpaceOAR results in favorable dosimetry to the organs at risk and portends excellent short-term quality of life as measured by the association with the patient reported outcome measures. Longer-term follow-up is ongoing and necessary to assess the long-term effect and association of the hydrogel.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655415PMC
http://dx.doi.org/10.1016/j.adro.2021.100755DOI Listing

Publication Analysis

Top Keywords

radiation therapy
16
prostate cancer
16
quality life
12
patient reported
8
dosimetry organs
8
organs risk
8
enrolled patients
8
epic-26 scores
8
aua-si scores
8
final follow-up
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!